Hitachi RAC-50DH7 Installation Manual Download Page 3

Pipe Connection

5

After connecting the refrigerant piping, seal the refrigerant pipes by using the factorysupplied insulation material.

Checking of drawing drain hose

6

Checking procedure after installation

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

 

 

Binder

4  &  5

6

7.1
7.2

7.3

Fig. 7-1

Fig. 7-1.

Fig. 7-2.

Fig. 7-2

7.4
7.5
7.6

Installation of wired remote controller

8

After unscrew the bond,
put the wired remote
control cord and fix
back with screw.

  7  Remote

      Controller

Wired remote
controller

4

6

5

The controller must
be hooked onto the
hook at the lower
part of the holder.
Push in the remote
controller in the
direction as shown
in figure below.

Remote

Controller

Holder for
Remote Controller

Screw (2 pieces)

Plug

The remote controller can be placed in its holder which is
fixed on wall  or beam.

To operate the remote controller at its holder, please
ensure that the unit can receive signal transmitted from
the controller at the place where the holder is to be fixed.
The unit will beep when signal is
received from the remote controller.
The signal transmission is weaken
by the fluorescent light. Therefore,
during the installation of the
remote control holder, please
switch on the light, even during day
time, to determine the mounting
location of the holder.

Installation of wireless remote controller (optional)

9

Setting of external static-pressure switch

10

Setting of External Pressure
Remove lid of electric box and
set the "STATIC PRESSURE"
switch.

‚O‚O

‚T‚P‚

Q‚S‚`

Protection of lead wire

12

Operation test

13

<

IA378: A 

>

CAUTION

The rubber strap used for
fixing the insulator should
not be tied with great force.
Otherwise, this will damage
heat insulation and causes
water condensation.

!

Pipe

Rubber strap tied with great force

AAA

size

battery

Wrap aluminium tape around PVC tube between electric box and indoor unit (cord band).

 

When connecting the wires via the wall’s recessed slot;

1. Fix the bottom casing to the wall by provided screw.
2. Assemble the top casing to the fixed bottom casing.

(Refer to the illustration below for detail installation)

Lead wires (3 strands) are
inserted through and
fastened via a rib-clip

Location of wall
mounting screw

Lead wires
connector

Wires

Wires

Lead wires
connector

Wall recessed wiring installation (Supplied)

W

all mounting scre

ws (2 pieces to be used)

Inside top wiring installation (Alternative)

Wires

Wires

Lead wires
(3 strands)

Lead wires
connector

Wiring installation illustrations

 

When the wires to be connected from the inside top portion of top casing;

1. Break off a perforated aperture located at the top portion of the bottom

casing by nipper. Smoothen the aperture by cutter.

2. Fix the bottom casing to the wall by provided screw.
3. Connect the wires to the lead wires connector.
4. Mount the wires through the provided slot on top casing.
5. Assemble the top casing to the fixed bottom casing

(Refer to the illustration below for detail installation)

Wall
mounting
screws
(2 pieces)

8

How To Connect The Optional Parts

(RAC Adapter, Weekly Timer, Wired Remote Control)

11

Weekly timer/
Wired remote controller

RAC Adapter

[For all optional part, please refer catalog for part number]

As for connecting to H-Link, a separately purchased RAC Adapter is required.

To install the wiring the electrical box cover must be opened.

Connect the connector of RAC adapter to CN1101.

Assemble back the cover of electrical box.

Please refer to the respective user manual of RAC Adapter for further details.

Please be careful not to damage lead wires by edge of plate when connecting the optional parts.

[For all optional part, please refer catalog for part number]

Connection to the electrical box:

Remove the cover of electrical box.

Connect the connector of Weekly Timer/wired remote controller to CN1102.

Assemble back the cover of electrical box.

Please refer to the respective user manual of Weekly Timer/wired remote controller for further details.

Please be careful not to damage lead wires by edge of plate when connecting the optional parts.

WEEKLY TIMER / WIRED REMOTE CONTROLLER

H-LINK

After unscrew the bond,
put the display panel cord
and fix again with screw.

Display panel cord

Connecting Cable

Connection Cord

Binder

Summary of Contents for RAC-50DH7

Page 1: ...e unit under direct sunshine or rain Besides ventilation must be good and clear of obstruction The air blown out of the unit should not point directly to animals or plants The clearances of the unit from top left right and front are specified in figure below At least three of the above sides must be open air Be sure that the hot air blown out of the unit and noise do not disturb the neighbourhood ...

Page 2: ...n Duct and Supply Duct 1 The return duct should be connected with the indoor through canvas ducts between inlet side of the indoor unit and ceiling of the room The supply duct should be connected with the indoor unit through canvas ducts in order to avoid abnormal sound vibration The unit is equipped with a pre drilled duct flange for the return and supply duct connection 2 Attach the vibration pr...

Page 3: ...efer to the illustration below for detail installation Lead wires 3 strands are inserted through and fastened via a rib clip Location of wall mounting screw Lead wires connector Wires Wires Lead wires connector Wall recessed wiring installation Supplied Wall mounting screws 2 pieces to be used Inside top wiring installation Alternative Wires Wires Lead wires 3 strands Lead wires connector Wiring i...

Page 4: ... Open the Top Back and Side cover of the unit Pull out the spacers inside Spacers are only for transportation purpose If not remove vibration and noise will occur Top cover FINAL STAGE OF INSTALLATION Insulation And Maintenance Of Pipe Connection 1 The connected terminals should be completed sealed with heat insulator and then tied up with rubber strap Please tie the pipe and power line together w...

Reviews: