CONNECTION OF POWER CORD

FINAL S

TA

GE OF INS

TALL

ATION

1 Power Source And Operation Test

Power Source

 WARNING

Never remodel the power plug nor extend the long-distance

cord.

Keep additional length for the power cord and do not render

the plug under external force as this may cause poor contact.

Do not fix the power cord with U-shape nail.

The power cable easily generates heat. Do not bring the

cable together with a wire or vinyl tie.

Operation test

Please  ensure  that  the  air  conditioner  is  in  normal  operating

condition during the operation test.

Explain to your customer the proper operation procedures as

described in the user' s manual.

If  the  indoor  unit  won't  operate,  check  the  cable  for  correct

connection.

Turn on the lamp in the room where the indoor unit is installed

and check the remote controller for normal operation.

2 Installation of Remote Controller

The remote controller can be placed in its holder which is fixed

on wall or beam.

To operate the remote controller at its holder, please ensure that

the unit can receive signal transmitted from the controller at the

place where the holder is to be fixed. The unit will beep when

signal  is  received  from  the  remote  controller.  The  signal

transmission is weaken by the fluorescent light. Therefore, during

the installation of the remote control holder, please switch on

the light, even during day time, to determine the mounting location

of the holder.

The controller must be hooked onto the hook at the lower part

of the holder. Push in the remote controller in the direction as

shown in figure below.

Force-cooling operation

When the service switch

of  the  outdoor  unit  is

pressed  for  1  or  more

seconds,  the  force-

cooling  operation  starts.

Use  this  mode  when

performing  the  failure

diagnosis  or  collecting

refrigerant  into  the

outdoor unit.

 CAUTION

Do not operate the unit for more than 5 minutes

while the spindle of the service valve is closed.

How to remove the front cover

1

Remove the front panel

Please remove and attach the front panel by both hands.

How to attach the front cover

1

Check that the drain pan is securely attached.

2

After installing the front cover onto the unit, hook three claws

at upper side of the cover securely. Then, push the center of

the front cover to lock the claws.

3

Tighten the two screws.

After opening the front panel by both hands.

1

Undo the right arm while pushing it inside.

2

Slide the front panel to right as shown in figure. Then remove

while pulling it to front.

2

Remove the filters.

3

After removing two screws, pull the center of the front cover

towards you and release the claws.

4

Pull the side faces (lower sections) of the front cover towards

you as shown in the figure and remove the cover.

Push up the [PUSH] sections at the bottom of the indoor unit and

pull the bottom plate towards you. Then the claws are released

from the stationary plate.

(The [PUSH] sections are indicated by 2 arrows in the right figure)

HOW TO REMOVE INDOOR UNIT

After completing the service switch

operation, be sure to keep the

switch pressed for one or more

seconds and stop the force-cooling

operation.

2

Remote controller

Screw (2 pieces)

Holder for Remote

Controller

Service switch (If the switch is

pressed for one or more seconds, the

force-cooling operation starts. If the

switch is pressed for additional one or

more seconds, the operation stops.)

Screw

Please remove side cover

4

Install the filter.

5

Slide the shafts of the right and left arms on the front panel

along the steps to insert the shafts into the holes till they stop.

After checking that the shafts are securely inserted, close the

panel.

[Push] mark positions

WARNING

If you cannot attach the side plate due to the connection cord, please

press the connecting cord in the direction to the front panel to fix it.

Be sure that the hooks of the side cover fixed in certainly

. Otherwise water

leakage may occur and this causes short circuit or faults.

The connecting cord should not touch to service valve and pipes. (it

becomes high temperature in heating operation.)

Wiring of the Outdoor Unit

Please remove the side cover for wire connection.

Checking for the electric source and the voltage range

Before installation, the power source must be checked and necessary wiring work must

be completed. To make the wiring capacity proper, use the wire gauge list below for the

wiring from house distribution fuse box to the outdoor unit in consideration of the blocked

rotor current.

IMPORTANT

Wire length

Wire gauge

up to   6m

1.6mm

2

up to 15m

2.5mm

2

up to 20m

4.0mm

2

Investigate  the  power  supply  capacity  and  other

electrical conditions at the installing location.

Depending on the model of room air conditioner to be

installed, request the customer to make arrangements

for the necessary electrical work etc.

The  electrical  work  includes  the  wiring  work  up  the

outdoor unit. In localities where electrical conditions

are poor, use of a voltage regulation is recommended.

Install outdoor for the room air conditioner within the

reaching range of the line cord.

cover

Earth terminal

IMPORTANT

Fuse Capacity

16A time delay fuse

Please mount the Outdoor unit of stable ground to prevent vibration and increase

of noise level.

Decide the location for piping after sorting out the different types of pipe available.

When removing side cover, please pull the handle after undoing the hook by pulling

it downward. Reinstall the side cover in the reverse order of the removal.

Please face this side (suction side)

of the unit to the wall.

Please remove terminal cover

when connecting the piping

and connecting cord.

CONDENSED WATER DISPOSAL OF OUTDOOR UNIT

There is holes on the base of Outdoor unit for condensed water to exhaust.

In order to flow condensed water to the drain, the unit is installed on a stand or a

block so that the unit is 100mm above the ground as shown figure.  Join the drain

pipe to one hole.

After installation, check whether the drain pipe clings to the base firmly.

Install the outdoor unit horizontally and make sure that condensate drains away.

In case of using in chilly area

Especially, in case that there are many snows by very cold in chilly area, condensed

water freezes on the base and may result not to drain.  In this case, please remove

the bush and the drain pipe at the bottom of unit.  (Left and center near discharge

portion of air, each 1 place).  It becomes smooth drain.

Ensure that the distance from the drain hole to the ground is 250 mm or more.

 CAUTION

Remove burr and jagged edge will cause leakage.

Point the side to be trimmed downwards during trimming to prevent copper

chips from entering the pipe.

Copper pipe

Trimming tool

Before flaring, please put on the flare nut.

A

Die

Die

Copper pipe

Please use

exclusive tool for

refrigerant R410.

Outer

A (mm) Rigid Flaring Tool

Diameter (Ø)

For R410A tool

For R22 tool

6.35 (1/4")

0 - 0.5

1.0

9.52 (3/8")

0 - 0.5

1.0

2 Pipe Connection

 CAUTION

In case of removing flare nut of a indoor unit, first remove

a nut of small diameter side, or a seal cap of big diameter

side  will  fly  out.  Free  from  water  into  the  piping  when

working.

Be sure to tighten the flare nut to the specified torque with

a torque wrench.

If the flare nut is overtightened, the nut may be split after a

long period has passed, and may cause a refrigerant  leak.

Please be careful when bending the copper pipe.

Screw in manually while adjusting the center. After that, use a torque wrench to

tighten the connection.

INS

TALL

ATION

 OF

 REFRIGERA

TING

 PIPES

 AND 

AIR

 REMO

VAL

Torque

wrench

Flare nut

Wrench

Small diameter side

6.35 (1/4")

13.7 – 18.6 (140 – 190)

Large diameter side

9.52 (3/8")

34.3 – 44.1 (350 – 450)

           Small diameter side 6.35 (1/4")

19.6 – 24.5 (200 – 250)

           Large diameter side 9.52 (3/8")

19.6 – 24.5 (200 – 250)

                      Valve core cap

12.3– 15.7 (125 – 160)

Valve

head cap

3 Remove of Air From The Pipe And Gas Leakage Inspection

AIR

 REMO

VAL

Procedures of using Vacuum Pump for Air Removal

As shown in right figure, remove the cap

of valve core.  Then, connect the charge

hose.  Remove  the  cap  of  valve  head.

Connect the vacuum pump adapter to the

vacuum  pump  and  connect  the  charge

hose to the adapter.

1

Fully tighter the "Hi" shuttle of the manifold

valve  and  completely  unscrew  the  "Lo"

shuttle.  Run the vacuum pump for about

10-15 minutes, then completely tighten the

"Lo"  shuttle  and  switch  off  the  vacuum

pump.

Loosen the spindle of the service valve

with  small  diameter  by  1/4  turn  and

tighten the spindle immediately after 5

to 6 seconds.

Remove  the  charging  hose  from  the

service valve.

2

Completely  unscrew  the  spindle  of  the

service valve (at 2 places) in anticlockwise

direction  to  allow  the  flow  of  refrigerant

(using Hexagonal Wrench key).

3

Tighten the cap of valve head.  Check the

cap's periphery if there is any gas leakage.

The task is then completed.

4

When the meter reaches - 101KPa

(-76cmHg)  during  pumping  fully

tighten the shuttle.

Meter showing

pressure

Closed

R410A

Manifold

valve

Vacuum

pump

Valve

Charge

hose

Vacuum

pump

adapter

When  pumping  starts,  slightly

loosen the flare nut to check of

air sucked in.  Then tighten the

flare nut.

The body of service

valve

Cap of

valve core

Hexagonal

wrench Key

Cap of valve

head

   Gas leakage inspection

Please use gas leakage detector to check if leakage

occurs at connection of Flare nut as shown on the

right.

If gas leakage occurs, further tighten the connection

to stop leakage.

OUTDOOR UNIT

1 Preparation of Pipe

Use a pipe cutter to cut the copper pipe and remove burr.

Cap of valve

head

Valve

 CAUTION

Do  not  touch  the  suction

port,  bottom  surface,  or

aluminum fin of the outdoor

unit.

Failure to do so may cause

an injury.

Outer diameter

of pipe (ø)

Pull at the 1  and 2  in the directions as shown by arrows to remove 

the cover.

Method to remove the low cover

Wiring of The Indoor Unit

For wire connection of the Indoor unit, you need to remove the front cover

under the body of the unit and terminal cover.

, the low cover

 WARNING

The naked part of the wire core should be 10mm fix it to the terminal tightly. Then

try to pull the individual wire to check if the contact is tight. Improper insertion may

burn the terminal.

Be sure to use only wire specified for the use of air-conditioner.

Please refer to the manual for wire connection and the wiring technique should

meet the standard of the electrical installation.

There is an AC voltage drop between the LN terminal if the power is on. Therefore,

be sure to remove the plug from its socket.

 WARNING

Leave  some  space  in  the  connecting  cord  for  maintenance

purpose and be sure to secure it with the cord band.

Secure  the  connecting  cord  along  the  coated  part  of  the  wire

using the cord band. Do not exert pressure on the wire as this

may cause overheating or fire.

When power supplies to Indoor Unit

WARNING

THIS APPLIANCE MUST BE

EARTHED.

Procedures of Wiring

Detail of cutting the connecting cord

30mm

10mm

10mm 70mm

Indoor Unit

10mm

50mm

10mm

50mm

Green + Yellow

Green + Yellow

Green + Yellow

Strip wires

Outdoor Unit

D

C

N

L

D

C

Indoor Unit

Outdoor Unit

Connecting Cord

Connecting Cord

AC 240V

1.6 or

2.0

2.0

Connect  the

earth  cord

D
C

After  remove  the  screw

and  cover,  and  put  the

connecting  cords  and  fix

the  cover  with  screw.

DRAIN HOLE

above

100mm

BASE

9  DRAIN PIPE

Outer diameter: 16 mm or more

Torque N

·

m

(kgf

·

cm)

Step

Shaft

Hole