13ー25
The LD301 blinks 13 times.
EEPROM reading error
The LD301 blinks 9 times.
Communication error
Communication error
The LD301 blinks once.
Reset stopped
The LD301 blinks 9 times.
Check the blinking frequency of the LD301.
No
Compressor stoppage
No
Correct the F cable connection.
Abnormal
Normal
Normal
Blinks 3times
Blinks 12 times
Blinking once
Other
Yes
Electrical parts abnormality
Check the F cable connection (for half insertion, connection by
using a thin cable, erroneous connection between terminal boards
Replace the outdoor electrical parts (in
the case of an abnormality in the
microcomputer or EEPROM).
Check that the indoor timer lamp blinks.
Check the indoor electrical parts.
(Check the temperature fuse in the
terminal board.)
Is the connector CN27
securely inserted?
(You may have forgotten to make the
correction after a self-check.)
emplace the outdoor electrical parts
(in the case of an abnormality in the
communication circuit).
Abnormality other
than compressor
stoppage
Run the product either by remote control or the
indoor forcible cooling switch.
Replace the outdoor electrical parts (in
the case of an abnormality in the
communication circuit).
Correct the abnormal location.
Abnormality in equipment other
than the electrical parts
The LD301 blinks once.
Reset stopped
If the indoor unit is either of the following states,
it will blink once.
·
Ionmist in progress
·
2 hours before the ON timer
Turn the power back on, run the
product either by remote control
or by using the forcible cooling
switch, and check the blinking
frequency of the LD301.
Replace the outdoor electrical parts
(in the case of an abnormality in the
reset circuit or microcomputer).
Conduct a check according to the
description of the LED blinking 9 times
given above.
Yes
Yes
No
No
Yes
Yes
Insert the connector CN
and conduct
a double-check.
If the LD301 is on, It is performing cooling or heating.
If the LD301 is on 2 second and off 0.3 second, the product is running with a heavy load. (This does not
constitute a failure.)
If the LD301 is bilnking each 0.25 second ,so please check the blinking number carefully of the lamp,and check it.
Identify the failure location.
CN27
disconnect
LD301 blinking frequency each 0.25 second,
please
check
it
carefully
.
1, 2 and 3, and other abnormalities).
27
* This page is only for
RAC-50FXB
Summary of Contents for RAC-25FXB
Page 38: ...RAC 25 35FXB MODEL 6ー2 ...
Page 39: ...RAC 50FXB MODEL 6ー3 ...
Page 68: ...11ー9 L N 300 330 A B Main parts C021 C023 500 450V RAC 25 35FXB MODEL ...
Page 72: ...11ー13 5 5 1 10 11 12 74 74 70 70 74 75 5 1 HIC P W B 74 70 75 ...
Page 74: ...11ー15 2A Fuse DC300 330V 7 7 1 ...
Page 75: ...11ー16 2A DC300 330V ...
Page 76: ...11ー17 L N 300 330 A B MODEL RAC 50FXB ...
Page 77: ...11ー18 300 330 C021 C023 500 450V 16V R249 33 ACT IP CUT 30 ...
Page 81: ...11ー22 5 5 1 74 74 70 70 74 75 5 1 HIC P W B 40 41 42 74 70 75 ...
Page 83: ...11ー24 2A Fuse DC300 330V 7 1 7 ...
Page 84: ...11ー25 2A DC300 330V ...
Page 94: ...13ー7 91 ...
Page 95: ...13ー8 IC531 IC531 IC531 ...
Page 96: ...13ー9 SELF DIAGNOSIS LIGHTING MODE RAC 25 35FXB MODEL ...
Page 97: ...13ー10 SELF DIAGNOSIS LIGHTING MODE RAC 50FXB MODEL ...
Page 119: ...14ー1 40 ...
Page 120: ...14ー2 Please set the DIP switch No 6 to ON accordingly Refer to page 59 ...
Page 121: ...14ー3 59 ...
Page 122: ...14ー4 ...
Page 131: ...Printed in Japan HRT TC NO 0842E RAF 25RXB RAC 25FXB RAF 35RXB RAC 35FXB RAF 50RXB RAC 50FXB ...