ADJUSTING THE AIR DEFLECTOR
1
2
Adjustment of the conditioned air to the left and right.
Hold the vertical air de
fl
ector as shown in the
fi
gure and adjust
the conditioned air to the left and right.
●
If the “ (AUTO SWING)” button is pressed once,
the horizontal air de
fl
ector swings up and down. If the
button is pressed again, the de
fl
ector stops in its current
position. Several seconds (about 6 seconds) may be
required before the de
fl
ector starts to move.
●
Use the horizontal air de
fl
ector within the adjusting range
shown on the right.
●
When the operation is stopped, the horizontal air de
fl
ector
moves and stops at the position where the air outlet
closes.
When cooling
dehumidifying
When heating
CAUTION
●
In “Cooling” operation, do not keep the horizontal air
de
fl
ector swinging for a long time. Some dew may form
on the horizontal air de
fl
ector and dew may drop.
RESET
Adjustment of the conditioned air in the upward and downward
directions.
The horizontal air de
fl
ector is automatically set to the proper
angle suitable for each operation. The de
fl
ector can be swung
up and down continuously and also set to the desired angle
using the “ (AUTO SWING)” button.
!
CAUTION
When operating the unit in cooling operation with the air de
fl
ector facing down and moving
automatically for a long period of time, water will condensed on the air de
fl
ector and drips
down occasionally. This will wet your furniture.
Summary of Contents for RAC-18GH5
Page 32: ... 31 MODEL RAC 18GH5 Note 1 200mm or more servicing space is required above the outdoor unit ...
Page 36: ... 35 CIRCUIT DIAGRAM Remote Control ...
Page 38: ... 39 BLOCK DIAGRAM MODEL RAS 18GH5 RAC 18GH5 ...
Page 42: ... 47 REFRIGERATING CYCLE DIAGRAM MODEL RAS 18GH5 RAC 18GH5 ...
Page 61: ...PM NO 0479E Printed in Malaysia RAS 18GH5 RAC 18GH5 ...