OUTDOOR UNIT

Removal Of Air From The Pipe And Gas Leakage Inspection

Gas Leakage Inspection

Please use gas leakage detector to check if leakage 
occurs at the connection of Flare nut as shown on 
the right.

If gas leakage occurs, further tighten the connection 
to stop leakage.

FINAL

 ST

AGE OF INST

ALLA

TION

Insulation And Maintenance Of Pipe Connection

1

 The connected terminals should be completely sealed with 

heat insulator and then tied up with rubber strap.

 Please tie the pipe and power line together with vinyl tape 

as shown in the  gure showing the installation of Indoor and 
Outdoor units. Then  

x

 their position with holders.

 To enhance the heat insulation and to prevent water 

condensation, please cover the outdoor part of the drain hose 
and pipe with insulation pipe.

 Completely seal any gap with putty.

  Installation Of Remote Controller

2

  Power Source And Operation Test

3

 The remote controller can be placed in its holder which is 

 

x

ed on wall or beam.

 To operate the remote controller at its holder, please ensure 

that the unit can receive signal transmitted from the controller 
at the place where the holder is to be  

x

ed. The unit will beep 

when signal is received from the remote controller. The signal 
transmission is weaken by the  uorescent  light.  Therefore, 
during the installation of the remote control holder, please 
switch on the light, even during day time, to determine the 
mounting location of the holder.

Power Source

!

 Please use a new socket. Accident may occur due to the use of 

old socket because of poor contact.

 Please plug in and then remove the plug for 2 – 3 times. This is 

to ensure that the plug is completely plugged into the socket.

 Keep additional length for the power cord and do not render the 

plug under e

x

ternal force as this may cause poor contact.

 Do not  

x

 the power cord with U-shape nail.

Operation Test

 Please ensure that the air conditioner is in normal 

operating condition during the operation test.

  E

x

plain to your customer the proper operation 

procedures as described in the user’s manual.

<

IA857: A 

>

The controller must 
be hooked onto the 
hook at the lower 
part of the holder. 
Push in the remote 
controller in the 
direction as shown 
in  gure below.

3

Procedures of using Vacuum Pump for Air Removal

As shown in right  gure, remove the cap 
of valve core. Then, connect the charge 
hose. Remove the cap of valve head. 
Connect the vacuum pump adapter to the 
vacuum pump and connect the charge 
hose to the adapter.

Fully tighten the “Hi” shuttle of the 
manifold valve and completely unscrew 
the “Lo” shuttle. Run the vacuum pump 
for about 10–15 minutes, then completely 
tighten the “Lo” shuttle and switch off the 
vacuum pump.

2

Completely unscrew the spindle of 
the service valve (at 2 places) in anti-
clockwise direction to allow the  ow  of 
coolant (using He

x

agonal Wrench key).

3

Remove the charge hose and tighten 
the cap of valve head. Check the cap’s 
periphery if there is any gas leakage. 
The task is then completed.

4

1

   Preparation of Pipe

1

 Use a pipe cutter to cut the copper pipe.

 Jagged edge will cause leakage.

 Point the side to be trimmed downwards during trimming to prevent copper 

chips from entering the pipe.

 Before  aring, please put on the  are  nut.

   Pipe Connection

2

INST

ALLA

TION OF REFRIGERA

TING PIPES 

AND 

AIR REMOV

AL

!

AIR REMOV

AL

 THIS APPLIANCE MUST BE EARTHED.

CONNECTION OF POWER CORD

 Please be careful when bending the copper pipe.

 Screw in manually while adjusting the center. After that, use of torque wrench to 

tighten the connection.

WARNING

!

In case that power is supplied from Indoor Unit

How to Remove The Front Cover

 Please use e

x

clusive 

tool

!

In case of removing  are nut of an Indoor unit,  rst remove a nut 
of small diameter side, or a seal cap of big diameter side will  y 
out. Prevent water from entering into the piping when working.

When the meter reaches - 101KPa 
(-76cmHg) during pumping, fully 
tighten the shuttle.

When pumping starts, slightly loosen the 
 are nut to check of air sucked in. Then 
tighten the  are  nut.

How to Attach the Front Cover

Sleeve of
protection pipe

Putty

Putty

 Mount the outdoor unit on stable ground to prevent vibration and 

  

increase of noise level.

 Decide the location for piping after sorting out the different types of 

pipe available.

Outer
Diameter (mm)

6.35

9.52

12.70

For R410A tool

0.0 

~

 0.5mm

0.0 

~

 0.5mm

0.0 

~

 0.5mm

For R22 tool

A (mm)

1.0mm

1.0mm

1.0mm

Power line

Control line

Outer

dia.of pipe

6.35 (1/4")

9.52 (3/8")

12.7 (1/2")

6.35 (1/4")

9.52 (3/8")

12.7 (1/2")

Valve 

head cap

Torque N·m

(kgf · cm)

13.7 – 18.6 (140 – 190)

34.3 – 44.1 (350 – 450)

44.1 – 53.9 (450 – 550)

19.6 – 24.5 (200 ~ 250)

19.6 – 24.5 (200 ~ 250)

29.4 – 34.3 (300 – 350)

12.3 – 15.7 (125 ~ 160)

Small dia. side

Large dia. side

Valve core cap

Small dia. side

Large dia. side

HITACHI

OFF

O

OFF

O

CAUTION

CAUTION

 The naked part of the wire core should be 10 mm and  

x

 it to the terminal tightly. Then try to pull the 

individual wire to check if the contact is tight. Improper insertion may burn the terminal.

 Be sure to use only power cables approved from the authorities in your country. For e

x

ample in Germany: 

Cable type: NYM 3

x

1.5mm

2

.

 Please refer to the installation manual for wire connection to the terminals of the units. The cabling must 

meet the standards of electrical installation.

 There is an AC voltage drop between the L and N terminals if power is on. Therefore, before servicing, 

be sure to remove the plug from the AC outlet or switch off the main switch.

 Do not make any connection in the middle of the connecting cable. It may cause the wire overheating, 

emit smoke and   re.

!

WARNING

Procedures of Wiring

WARNING

 If you cannot attach the side cover due to the connecting 

cord, press the connecting cord in direction to the front panel 
to  

x

 it.

 Be sure that the hooks of the side cover is  

x

ed in certainly. 

Otherwise water leakage may occur and this causes short 
circuit or faults.

 The connecting cord should not touch to service valve and 

pipes. (It becomes high temperature in heating operation.)

Checking for the electric source and the 
voltage range

 Before installation, the power source must be checked and necessary wiring 

work must be completed. To make the wiring capacity proper, use the wire 
gauges list below for the lead-in from a pole transformer and for the wiring 
from a switch board of fuse bo

x

 to the main switch and outdoor unit in 

consideration of the locked rotor current.

Cable length

up to 

1

6m

up to 15m

up to 25m

Wire cross-section

1.6mm

2

2.5mm

2

4.0mm

2

IMPORTANT

Wiring of The Outdoor Unit

 Please remove the side cover for wire connection.

!

Wiring Of The Indoor Unit

  For wire connection of the Indoor unit, you need to remove low cover and front cover.

Method to remove front cover.

  Refer to “FINAL STAGE OF INSTALLATION – How to Remove The Front Cover”.

Method to remove the low cover

 Pull the cover at  1  and  2  in the directions as shown by arrows to 

remove the cover.

CAUTION

Lo

Hi

Meter showing pressure

Closed

Manifold valve

Vacuum 
pump

Valve

Charge hose

Valve

Vacuum pump
adapter

CONDENSED WATER DISPOSAL OF OUTDOOR UNIT

 

There are holes on the base of Outdoor unit for condensed 
water to e

x

haust.

  In order to  ow condensed water to the drain, the unit must be installed 

as shown. The unit must be 100mm and above the ground. Join the drain 
pipe to one hole.

  At  rst insert one portion of the hook to the base (Portion A), then pull the 

drain pipe in the direction shown by the arrow while inserting the hook 
into the base. After installation, check whether the drain pipe cling to the 
base  rmly.

Drain Pipe

9

A

DRAIN PIPE

BASE

When Using and Installing In Cold Areas 

When the air conditioner is used in low temperature and in snowy conditions, 
water from the heat e

x

changer may freeze on the base surface to cause 

poor drainage. When using the air conditioner in such areas, do not install 
the bushings. Keep a minimum of 250mm between the drain hole and the 
ground. When using the drain pipe, consult your sales agent.

     For more details, refer to the installation
 

Manual for Cold Areas.

Fuse Capacity

10A time delay fuse

After remove the screw 
and cover, and put the 
connecting cords and  

x

 

the cover with screw.

  Investigate the power supply capacity and other electrical 

conditions at the installation location.

  Depending on the model of room air conditioner to be installed, 

request the customer to make arrangements for the necessary 
electrical work etc.

  The electrical work includes the wiring work up the outdoor. In 

localities where electrical conditions are poor, use of a voltage 
regulation is recommended.

C D

Fuse Capacity

15A time delay fuse

For RAC-14LH1 only

IMPORTANT

Outdoor supply cords shall not be lighter 
than polychloroprene sheathed  e

x

ible 

cord with code designation 60245 IEC 57. 

CAUTION

!

10mm

100mm ABOVE

FRONT

W

ALL

BRACKET

BACK

Ensure that the front side 
of unit is higher than the 
back by 10mm

GRN + YEL

Strip wires

Outdoor

Unit

Indoor

Unit

Check that the drain pan is securely attached.

After installing the front cover onto the unit, hook three 
claws at upper side of the cover securely. Then, push the 
center of the front cover to lock the claws.

Tighten the two screws.

Connect the wire connector. Close the electrical cover.

5 Install 

the 

 

lter.

Slide the shafts of the right and left arms on the washable 
panel along the steps to insert the shafts into the holes 
till they stop. After checking that the shafts are securely 
inserted, close the panel.

 1  Remove the front panel.

 

Please remove and attach the front panel by both hands.

 

After opening the front panel by both hands.

1

  Undo the right arm while pushing it inside.

2

  Slide the front panel to right as shown in  gure. Then 

remove while pulling it to front.

 2  Remove the  lters.

  3  Open the electrical cover. Disconnect the wire connector.

 4  After removing two screws, pull the center of the front 

cover towards you and release the claws.

 5  Pull the side faces (lower sections) of the front cover 

towards you as shown in the  gure and remove the 

            

cover.

GRN + YEL

(EN2) INS RAS-8-10-14LH2(B)   1

3/20/12   9:59 AM