Hitachi RA-08MDF Operation And Installation Manual Download Page 5

– 3 –

Circulation Function

 

During circulation operation, compressor will not run and there is no cooling operation with only
fan running.

When the setting temperature is higher than room temperature, fan will stop running.

CIRCULATION OPERATION

Press the 

 (CIRCULATION) button so that the display indicates   pointing to 

button. 

Circulating operation starts with a beep.

Press the FAN SPEED button and select the desired FAN SPEED (the display indicates 
your choice).

Press the temperature control button to set to the desired temperature.

As the settings are stored in memory in the remote controller, you only have to press the

(CIRCULATION) button next time.

3

 Press the 

 (STOP) button to stop operation.

STOP

1

2

HOW TO SET THE SLEEP TIMER

Press the     (SLEEP TIMER) button, and the display changes as shown below.

SLEEP TIMER:

 The device will continue working for the designated number of hours 

and then turn off.
Point the signal window of the remote controller toward the indoor unit, and press 
the SLEEP TIMER button.
The timer information will be displayed on the remote controller. The TIMER lamp 
lights with a beep from the indoor unit. 

SLEEP 
TIMER

Mode

SLEEP TIMER

4

4

4

1

Indication

    1 hr       2 hrs       3 hrs          10 hrs      11 hrs      12 hrs

Cancel sleep timer

4

4

After sleep timer time is up and when press sleep timer button again, the timer will be set as last setting.

Sleep timer effective only once.

NOTE

4

Cooling

“          ”

and

dehumidifying

“          ”

Explanation of the sleep timer

The device will control the FAN SPEED and room temperature automatically so as to be quiet and good for people’s 
health.
You can set the sleep timer to turn off after 1 to 12 hours. The FAN SPEED and room temperature will be controlled 
as shown below.

Function

Operation

The room temperature will be 
controlled 2°C above the setting 
temperature and the FAN SPEED 
will be set to LOW setting 1 hour 
after the setting of the sleep timer.

Summary of Contents for RA-08MDF

Page 1: ... not adjust the vertical deflectors position by hand or any other object CAUTIONS AIR EXHAUST LEVER WASABI AIR PURIFYING FILTER Set the air exhaust lever to the down OPEN position for air ventilation in the room The air exhaust lever should normally be kept in up CLOSE position during cooling operation and in the case of typhoon NOTES ON OPERATION TEMPERATURE AND HUMIDITY Avoid to use the room air...

Page 2: ...t dry cloth When it is excessively dirty wipe it with a soft cloth dampened with mild soap then wipe it again thoroughly with a soft dry cloth The suction grille can also be removed and be washed with water and mild soap Remove the suction grille in the following manner 1 Remove the suction grille by pulling the bottom corner and slightly lift up the suction grille 2 3 Pull downward to unhook the ...

Page 3: ...operation RESET button STOP button Press this button to stop the operation SLEEP TIMER button Press this button to set the sleep timer FAN SPEED button Press this button to change the fan speed Every time you press this button the intensity of circulation will change from AUTO to HI to MED to LOW AUTO SWING button Press this button to set auto swing or stop angle of the vertical air deflector TEMP...

Page 4: ...ller you only have to press the COOLING button next time 1 2 STOP 3 Dehumidifying Function When the room temperature is higher than the temperature setting The device will start to dehumidify and lower the room temperature to the preset level When the room temperature is lower than the temperature setting Dehumidifying will be performed at the temperature setting slightly lower than the current ro...

Page 5: ...rking for the designated number of hours and then turn off Point the signal window of the remote controller toward the indoor unit and press the SLEEP TIMER button The timer information will be displayed on the remote controller The TIMER lamp lights with a beep from the indoor unit SLEEP TIMER Mode SLEEP TIMER 4 4 4 1 Indication 1 hr 2 hrs 3 hrs 10 hrs 11 hrs 12 hrs Cancel sleep timer 4 4 After s...

Page 6: ...t use new and old batteries or different kinds of batteries together 2 Take out the batteries when you do not use the remote controller for 2 months or longer 3 Use high quality and high performance AAA batteries to avoid short operating life and electrolyte leakages When using the remote controller if there is no response from the air conditioner or the remote controller display is dim please try...

Page 7: ... IA0000 A RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF ...

Page 8: ...0 A RA 13MDF RA 13MEDF ࡌ ઠ ྫ ປ ሣ ૃ ጠ ᘞ Ă ቜ ϵ ཆ ϱ ა ݣ ቜ շ ັ Ӱ ྫ ປ ሣ Ё Ą 20mm ʰ 20mm ʰ RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF RA 08MDF RA 08MEDF RA 10MDF RA 10MEDF RA 13MDF RA 13MEDF 15Њઉ ᔞ ዢ ...

Page 9: ... 1 ଂ ...

Page 10: ... 2 ...

Page 11: ... 3 ...

Page 12: ... 4 IA0000 A ...

Reviews: