background image

1. In order to disassemble and repair the

unit in question, be sure to disconnect
the power cord plug from the power
outlet before starting the work.

2. If it is necessary to replace any parts, they should be replaced with respective genuine parts for the unit, and the 

replacement  must be effected in correct manner according to the instructions in the Service Manual of the unit.

3. After completion of repairs, the initial state should be restored.
4. Lead wires should be connected and laid as in the initial state.
5. Modification of the unit by the user himself should absolutely be 

prohibited.

6. Tools and measuring instruments for use in repairs or inspection should be accurately calibrated in advance.

7. In installing the unit having been repaired, be careful to prevent the occurrence of any accident such as electrical 

shock, leak of current, or bodily injury due to the drop of any part.

8. To check the insulation of the unit, measure the insulation resistance between the power cord plug and grounding 

terminal of the unit.
The insulation resistance should be 1M

 or more as measured by a 500V DC megger.

9. The initial location of installation such as window, floor or the other should be checked for being safe enough to 

support the repaired unit again.
If it is found not so strong and safe, the unit should be installed at the initial location after reinforced or at a new location.

10. Any inflammable object must not be placed 

about the location of installation.

11. Check the grounding to see whether it is proper 

or not, and if it is found improper, connect the
grounding terminal to the earth.

SAFETY  DURING  REPAIR  WORK

First, I must disconnect
the power cord plug 
from the power outlet.

If the  contacts of  electrical  parts are

 defective,  replace  the electrical  parts

 without  trying  to repair  them. 

DANGER

 1

Summary of Contents for R-Z570ERU9X (STS)

Page 1: ... PARTS 7 9 PARTS LIST MODEL R Z570ERU9X STS 10 13 SPECIFICATIONS TYPE DOUBLE DOOR MODEL POWER SOURCE 1Ø 220 240V 50Hz POWER INPUT W TOTAL CURRENT A NET 475L GROSS 531L W 740 D 736 H 1795 NET WEIGHT Kgs 81 R Z570ERU9X STS REFRIGERATOR H C P T NO 2103E SERVICE MANUAL DIMENSIONS mm JAN 11 R Z570ERU9X 106 0 6 VOLUME PT NO 2103E R Z570ERU9X STS HITACHI ...

Page 2: ... such as electrical shock leak of current or bodily injury due to the drop of any part 8 To check the insulation of the unit measure the insulation resistance between the power cord plug and grounding terminal of the unit The insulation resistance should be1MΩ or more as measured by a 500V DC megger 9 The initial location of installation such as window floor or the other should be checked for bein...

Page 3: ...ONIC CONTROL CONTROL FREEZER ELECTRONIC CONTROL DEFROSTING WAY HEATER DEFROSTING INITIATION F AUTOMATIC R AUTOMATIC SYSTEM TERMINATION F AUTOMATIC R AUTOMATIC EVAPORATION FORCED FREEZER MAIN PARTS COMPONENTS COMPRESSOR PHASE RATE VOLTAGE V RATE FREQUENCY Hz POLE NUMBER CONNECTION M C 16 5 Ω S C 23 9 Ω STARTING CURRENT A 7 91 A PTR Z610EMX 027 YES R Z570ERU9X UP HINGE SENSOR PTR Z400V 050 RESISTANC...

Page 4: ...f time 10min Pre Cool time 30min Basic operation time chart of 508L 550L REF Comp On time t1 t2 t3 t4 12h High Priority High Priority Condition Comp Off time Off Defrosting Off F sensor High temp On F sensor Low temp Off Condition Damper Comp off Close R sensor High temp Open R sensor Low temp Close Condition R Fan R Door open Off Comp on On Comp off Off Off time 10min High Priority Defrosting 30s...

Page 5: ... 38k 0 34 62k 5 8 15k 5 4 94k 5 4 97k 5 26 52k 0 6 29k 10 3 88k 10 3 90k 10 20 50k 5 4 90k 15 3 08k 15 3 09k 15 15 99k 10 3 85k 20 2 46k 20 2 47k 20 12 00k 15 3 05k 25 1 98k 25 1 98k 25 9 97k 20 2 43k 30 1 60k 30 1 61k 30 7 97k 25 1 96k 35 1 31k 40 1 08k 35 6 42k 30 1 59k 40 1 07k 50 0 74k 40 5 20k 61 0 51k 60 0 51k 61 0 50k 62 2 32k TC sensor F sensor R sensor D sensor Normal range Abnormal range...

Page 6: ...Blink 4 times D sensor abnormal D sensor value abnormal No defrosting 5 Blink twice EEPROM data abnormal EEPROM data abnormal Display error code 6 Blink 12 times R Fan motor abnormal or 12V drops R Fan motor abnormal or 12V drops R Fan motor stops and retry after 3min 7 Blink 4 times Defrosting circuit abnormal Defrosting continues even after 2 hours After 2 hours stop defrosting and display error...

Page 7: ...CIRCUIT DIAGRAM MODEL R Z570ERU9X 6 ...

Page 8: ...19 1 1 2 2 3 3 4 6 4 4 4 5 6 8 7 9 10 12 11 15 14 16 17 20 13 13 21 18 23 MODEL R Z570ERU9X 7 ...

Page 9: ...72 73 60 59 74 72 71 70 30 31 32 43 42 44 45 46 47 49 50 51 52 53 54 61 62 63 64 41 33 33 33 34 35 36 37 39 38 40 65 66 68 40 67 69 28 24 27 29 25 55 56 57 58 58 MODEL R Z570ERU9X 8 ...

Page 10: ...MODEL R Z570ERU9X 108 9 ...

Page 11: ... Z550AM 001 DOOR BASKET F 475 07 2 14 PTR Z70FGD9X 001 HANDLE PIPE R SLS STS 1 15 PTR Z610EMX 004 DOOR PANEL R STS 1 16 PTR 578AMX 005 D STOPPER R STS SS 1 17 PTR 578AM 015 D GASKET R 475 1 18 PTR Z610EMX 005 DOOR PANEL R ASS Y STS 1 19 PTR 44A4P 003 E CASE 475 1 20 PTR Z550AM 002 DOOR BASKET R1 475 07 1 21 PTR Z600AM 001 DOOR POCKET R2 475 07 1 22 PTR Z550AM 003 DOOR BASKET R3 06 1 23 PTR Z550AM ...

Page 12: ...SENSOR HOLDER 1 44 PTR Z550AM 023 EVAPORATOR 475 07 1 45 PTR Z610EMX 015 THERMAL FUSE 1 46 PTR Z610EMX 016 F SENSOR 1 47 PTR Z610EMX 017 FAN MOTOR 1 48 PTR Z610EMX 018 M PLATE 1 49 PTR Z610EMX 019 FAN GUARD 1 50 PTR 48A4P 001 F GRILL 475 1 51 PTR Z610EMX 020 HEATER COVER 1 52 PTR Z610EMX 021 R HEATER 1 53 PTR Z571ARS6 001 HEATER COVER 475 1 54 PTR Z660EMX 012 CONTROL PANEL ASS Y 1 55 PTR Z400V 043...

Page 13: ...73 PTR Z610EMX 028 LO HINGE 1 74 PTR 400WP 038 ADJUSTER L 1 75 PTR Z660AGS6D 003 SCREW 4 76 PTR 400WP 042 BACK HANDLE L 1 77 PTR 400WP 041 BACK HANDLE R 1 78 PTR Z660EMX 013 UP HINGE COVER R 1 79 PTR Z400V 050 TC SENSOR 1 80 PTR N39WS 061 HEX BOLT UP HING 3 81 PTR W720FMX 081 UP HINGE R 1 82 PTR 25A3P 022 DOOR SWITCH 2 83 PTR Z700AM 029 CENTER HINGE 07 1 84 PTR Z70FGD9X 009 PLUG CORD 1 85 PTR Z610...

Page 14: ...TR Z570EU9 007 COMPRESSOR BASE 475 1 99 PTR 923V 061 ROLLER PIN 2 100 PTR SF37WVPTH 006 ROLLER 2 101 PTR Z530ARP7 003 UP CARTON475 3D 08 1 102 PTR Z550AM 030 UP CUSHION 07 1 103 PTR Z66ARP7 003 SIDE CUSHION 2 104 PTR Z570ERU9 006 CARTON BOX R Z570ERU9X STS 1 105 PTR Z550AM 033 FRONT CUSHION 1 106 PTR Z600AS7KV 007 POLY BAG WY 07 1 107 PTR Z570EG9 007 DOOR CUSHION 475 1 108 PTR Z550AM 034 CARTON BA...

Reviews: