background image

E-3

Stick cleaner handle operation

When folding the stick cleaner handle

Risk of injury

Do not hold the area around the rotating 
section of the stick cleaner handle when 
folding or raising the stick cleaner handle.

1

Slowly rotate and fold.

2

Slowly rotate.

Handle

storage button

WARNING

Rotating section

When raising the stick cleaner handle, 

slowly rotate and raise it until you hear a "click" sound.

Hold the stick cleaner handle and press the handle 

storage button to release the stick cleaner handle lock

Attachment accessories

Crevice nozzle (1 pc.) 

→ 

(P.E-11)

Multi angle brush nozzle 

→ 

(P.E-11)

Brush (1 pc.)

Multi angle nozzle (1 pc.)

Maintenance brush

(1 pc.)

Attachments

Dry Mop Head (1 pc.)

Charging station

Base (1 pc.)

Stand (1 pc.)

Part names

and assembly

Summary of Contents for PV-XE90

Page 1: ... and assembly Safety precautions Notes on use E 2 E 4 E 7 Contents Before use How to use When Finished cleaning Appendix Emptying the dust case Checking the Max line Detaching the dust case Emptying the dust case Emptying the filters Stowing the cleaner How to store Maintenance Stick cleaner attachments attachment accessories Dust case filters cyclone chamber Dry Mop Head E 12 E 12 E 12 E 12 E 13 ...

Page 2: ...Click Stick cleaner P E 9 E 10 E 14 Dust case Sponge filter Cyclone chamber Clean filter Dust case P E 12 E 13 E 15 Maintenance brush Groove Exhaust Handy cleaner handle The battery is built into the handy cleaner handle Handy cleaner control button P E 9 The attachment accessories can be attached to the protrusion on the charging station base The multi angle nozzle can be attached to the end of t...

Page 3: ...age button WARNING Rotating section When raising the stick cleaner handle slowly rotate and raise it until you hear a click sound Hold the stick cleaner handle and press the handle storage button to release the stick cleaner handle lock Attachment accessories Crevice nozzle 1 pc P E 11 Multi angle brush nozzle P E 11 Brush 1 pc Multi angle nozzle 1 pc Maintenance brush 1 pc Attachments Dry Mop Hea...

Page 4: ...ects Do not carry or store with metal necklaces hairpins etc The product may fail or the battery may short circuit and cause leaking heat generation rupturing or fire Do not throw into fires or apply heat The internal battery may rupture and cause fire Content that prompts warning or attention Prohibited content that must not be performed Directive content that must be performed Meaning of symbols...

Page 5: ...ed charging station to charge other types of rechargeable batteries or non rechargeable batteries z During charging the stick cleaner with the charging station must be placed in a well ventilated area Doing so may cause fire or electrical shock Handle others Do not hold the area around the rotating section of the stick cleaner handle when folding or raising the stick cleaner handle This may cause ...

Page 6: ...reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Only allow children at least 8 years old to use the charging station Give sufficient instruction so that the child is able to use the charging station in a safe way and explain that it is ...

Page 7: ...ter such as tap water After washing your eyes immediately consult a doctor This may cause eye failure WARNING If the battery leaks gives off an abnormal smell becomes discolored deformed or damaged after it is dropped etc do not use it Doing so may cause heat generation rupture fuming or fire A wet floor may cause damage Keep out of reach of babies and toddlers This may cause electric shock or inj...

Page 8: ... of the operating time When you use the cleaner for the first time or when you have not used it for a long period of time the charge time may be long or operating time may be short Charging the battery near a radio may cause noise and make the radio broadcast difficult to hear Plug in the charging station and the radio at power sockets 2 or more meters apart from each other when charging Note Char...

Page 9: ...cleaner Press the control button of the handy cleaner 1 2 Risk of malfunction Do not attach or detach the handy cleaner during operation Risk of injury or damage to the floor Do not prop up the stick cleaner while the handy cleaner is detached The stick cleaner will become unstable Set it on the charging station lean it against an object so that it does not fall or lay it down on the floor CAUTION...

Page 10: ...u can clean proficiently by moving the head back and forth across floor Stick cleaner Use in accordance with the floor type Risk of damage to the floor The floor may be damaged if it is easily damaged such as cypress or padded flooring Padded flooring is flooring where the surface is cushioned using vinyl chloride etc Risk of damage to the floor If dust gets tangled in the wheels the wheels cannot...

Page 11: ...e handy cleaner Risk of damage Do not press against areas that are particularly easy to be damaged such as pianos CAUTION It is a free rotating nozzle that can reach far above furniture and into crevices Inlet Crevice nozzle You can change to various angles according to the area to be cleaned If you are using the nozzle with the brush removed use it to collect dust on clothing curtains etc 3 angle...

Page 12: ...ressing the dust disposal button When you complete cleaning stop operation and check the Max line Empty the dust case before exceeding the Max line Max line Dust case M ax Dust case Handy cleaner handle Dust disposal button CAUTION Risk of injury or damage to the floor Pressing the dust disposal button while not holding the dust case will cause the dust case to fall Emptying the dust case Hold the...

Page 13: ...n the environment and the season Clean filter Cyclone chamber Sponge filter Sponge filter Stand Maintenance brush Clean filter Maintenance brush Attach the sponge filter to the clean filter Align the U marks of the cyclone chamber and clean filter and firmly press all the way Attach the sponge filter and clean filter to the cyclone chamber 3 When attaching the clean filter align the U marks of the...

Page 14: ...handle and press the handle storage button to release the handle lock Slowly rotate and fold CAUTION Risk of injury or damage to the floor When carrying the cleaner and placing it on the floor while it is set on the charging station the stick cleaner may detach Do not leave the stick cleaner unattended while it is propped up Do not store in places of high temperature such as near heaters or under ...

Page 15: ... ventilated environment such as outdoors or wear a mask and avoid breathing in the dust Cyclonic cleaners have the advantage of not requiring paper bags but to clean with high suction power we recommend frequent maintenance To clean we recommend frequent filter maintenance Note Remove the cyclone chamber from the dust case 1 Wash the dust case with water 2 Thoroughly air dry the dust case The dryi...

Page 16: ... injury You may have unintentionally vacuumed sharp objects such as glass shards or pins Be careful when performing maintenance Gently remove the dust stuck inside before washing with water Note ࡵ ࡿ ࡣࡎࡍ R e le a s e R e le a s e Lock Lock Cyclone chamber lid Handle Cyclone chamber Cyclone chamber lid Re lea se Lock ࡵ ࡿ ࡣࡎࡍ R e le a s e R e le a s e Lock Lock Cyclone chamber lid Handle Adjust the h...

Page 17: ...nally vacuumed sharp objects such as glass shards or pins Be careful when performing maintenance CAUTION Attach the sponge filter to the clean filter Align the U marks of the cyclone chamber and clean filter and firmly press all the way Attach the sponge filter and clean filter to the cyclone chamber 4 When attaching the clean filter align the U marks of the cyclone chamber and clean filter and fi...

Page 18: ...es attach it to the handy cleaner handle Do not use cleansers bleach etc and do not wash using a washing machine Also do not dry it with hot air such as that from a hair dryer This may cause a deterioration in performance damage or deformation Gently remove the dust stuck inside before washing with water Do not use a brush other than the supplied maintenance brush Doing so may cause damage After w...

Page 19: ...nishing using the stick cleaner while the battery was not completely discharged P E 8 Operating time is short even after charging The battery capacity may be temporarily recovering poorly Repeat the procedure of using the cleaner until the battery is exhausted and charging fully 2 or 3 times The cleaner does not operate Is the remaining battery level low P E 14 Securely attach it Is the handy clea...

Page 20: ...urself Please consult with the dealer If the problem persists When disposing of the product Li ion 10 Please check with your municipality and follow recycling regulations Recycling rules may vary depending on the local governing policy This product uses a lithium ion battery Lithium ion batteries are a valuable recyclable resource The battery is built into the handy cleaner handle The battery is a...

Page 21: ...station Attachments Dimensions when stored L W H Attachment accessories PV XE90 DC 18 V 2 000 mAh 0 25 L Lithium battery 5 cells built into handy cleaner handle 2 5 kg 1 4 kg High Approx 16 minutes Standard Approx 45 minutes At full charge new battery 20 C 170 mm 270 mm 1 100 mm 420 mm 115 mm 127 mm AC 100 240 V 50 60 Hz 0 25 0 14 A DC 21 4 V 0 6 A Approx 4 hours depends on conditions such as room...