background image

2

OPERATION & INSTALLATION MANUAL FOR PC-RLH8/10

3  INSTALLATION OF WIRELESS RECEIVER KIT 

CAUTION:

 

Pay attention to the following installation procedures.  If not, it may drop from the panel, 
resulting in a serious accident. 

„

PC-RLH8

1)  Install the wireless receiver kit, the indoor unit and the air panel at the same time. 
2)  In case that the wireless receiver kit is installed after installing the indoor unit, turn off the 

power source of the indoor unit and remove the air panel. 

3)  This receiver kit can be installed at the position 1,2,3 or 4 

4)  Remove the cover of indoor unit electrical controlbox and connect the cable to the terminal 

board (white) as shown below. 

Air Panel 

Terminal Board 

Indoor Unit 

Electrical Control Box 

   PCB 

  (White) 

  Mark Band "B" 

  Mark Band "A" 

Connecting Cable 

Summary of Contents for PC-RLH10

Page 1: ... work without referring to our installation manual No realice la instalación de este equipo sin antes consultar este manual de instalación Bei der Installation unbedingt die Hinweise in der Installationsanleitung beachten Consulter notre manuel avant de réaliser une quelconque installation Realizzare l installazione seguendo quanto indicato in questo manuale Nao inicie os trabalhos de montagem sem...

Page 2: ......

Page 3: ...mmable gas is detected Where the sea is near in the salty acid or alkaline environment DO NOT install the indoor unit outdoor unit within approximately 3 meters from strong electromagnetic wave radiators such as medical equipment In case that there is electric noise at the power source for the indoor unit provide a noise filter Do not turn ON the power source unless the preparation for test runnin...

Page 4: ...he air panel at the same time 2 In case that the wireless receiver kit is installed after installing the indoor unit turn off the power source of the indoor unit and remove the air panel 3 This receiver kit can be installed at the position 1 2 3 or 4 4 Remove the cover of indoor unit electrical controlbox and connect the cable to the terminal board white as shown below Air Panel Terminal Board Ind...

Page 5: ...ocedure o Draw out the connecting cable from the pocket and connect the connecting cable and the wire of the receiver kit After connecting the cable wrap the connector with the cover and fix them with a band p Hook the band on the rear side of the receiver kit at the pin of the air panel as shown bellow q Hook L shaped nail on the rear side of receiver kit at the square hole of the air panel Air P...

Page 6: ...he indoor unit and the air panel at the same time 2 In case that the wireless receiver kit is installed after installing the indoor unit turn off the power source of the indoor unit 3 Remove the right resin side cover 1 Open the air intake grille 2 Remove the attaching screw M4 of resin cover side cover 3 Slide the resin side cover forward as shown below 4 Remove the remote control cover 1 Insert ...

Page 7: ...reless receiver kit and drain pan 6 Lead the cable into the electrical box with other wires 1 Attach the insulation Factory Supplied to the edge of the side platein order to protect the cable as shown in the figure below Wireless Receiver Kit Enlarged View Side Plate Insulation Factory Supplied Cushion Cable for Wireless Receiver Kit Drain Pan Cable for Wireless Receiver Kit Drain Pan Side Plate R...

Page 8: ...able bind up the remaining cable lenght portion by band Factory Supplied and put them in electrical control box RPC 2 0 to 3 0 HP RPC 4 0 to 5 0 HP Printed Circuit Board Terminal Board White Cable for Wireless Receiver Kit Electrical Box for Indoor Unit Mark Band A Mark Band B Terminal Board White Cable for Wireless Receiver Kit Printed Circuit Board Electrical Box for Indoor Unit Mark Band A Mark...

Page 9: ...Control Switch Setting for Simultaneous Operation ON 1 2 3 4 PC RLH10 2 Optional Setting for Dip Switch SW3 Operation Function DIP Switch Setting SW3 Setting of Sub Receiver kit ON 1 2 3 4 Identifying of Indoor Units ON 1 2 3 4 Switch COOL Switch HEAT Dip Switch SW3 Factory Supplied Rear Side of Indoor Unit Remove the screw Cover Remove two screws and open the case Switch COOL Switch HEAT Dip Swit...

Page 10: ...TE During the emergency operation the LED yellow blinks 0 5 second ON 0 5 second OFF 3 Alarm Code Indication In case that some trouble occures because of activation of safety device etc RUN red lamp blinks 0 5 second ON 0 5 second OFF Refer to the Installation Manual for outdoor unit about Alarm Code List Alarm Code indicates the blinking times of DEF green lamp and FILER yellow lamp as shown bell...

Reviews: