14
INSTALLATION MANUAL
4.1.6. TIMER OPERATION PROCEDURE
Setting current day and time
1. Hold down the SELECT (
E
) DAY switch for more than 3 seconds to change to current day setting mode.
SET is indicated and the day blinks. All the days except the current day are indicated.
:
SET Mon Tue Wed Thu Fri
Sat
Sun
2. Hold down the SELECT (
E
) DAY switch until the current day blinks, then press OK.
The date is indicated, and the time blinks.
:
SET Mon Tue Wed Thu Fri
Sat
Sun
3. Press the SELECT (
FE
) DAY / SCHEDULE switches to adjust the “hour” setting, and then press again.
“Hour” is indicated and “minutes” blinks.
:
SET
Wed
4. Press the SELECT (
FE
) DAY / SCHEDULE switches to adjust the “minutes” setting, and then press again.
The current time setting mode ends and returns to normal mode. “Minutes” is indicated and the SET indication
goes out. The “seconds” start from zero.
:
Wed
Setting the timer (programming)
1. Press the TIMER switch. SET and SCHEDULE are indicated. Schedule number “1” blinks and other numbers
are indicated.
:
SET
1234S
SCHEDULE
ON
4
OFF
:
2. When the SCHEDULE switch (
F
) is pressed, the schedule number moves
[1]
[2]
[3]
[4]
[S]
[1]
….
Select [S] to set the ON/OFF time and temperature shifts.
By pressing the TIMER switch, the SET and SCHEDULE indicators go out and the mode changes back to
normal.
:
SET
1234S
ADDS
SCHEDULE
RNkHR
ON
4
OFF
:
3. When the OK switch is pressed, the selected schedule number is indicated. The other schedule number
indicators go out, and the ON time “hour” indicator for the number selected blinks.
:
SET
1
SCHEDULE
ON
4
OFF
:
4. Press the SELECT (
FE
) DAY / SCHEDULE switches to adjust the “hour” setting, and then press again.
“Hour” is indicated and “minutes” blinks.
:
SET
1
SCHEDULE
ON
4
OFF
:
5. Press the SELECT (
FE
) DAY / SCHEDULE switches to adjust the “minutes” setting, and then press again.
“Minutes” is indicated and the OFF time “hour” setting blinks.
:
SET
1
SCHEDULE
ON
4
OFF
:
6. Set the OFF time the same way as the ON time. After setting the “minutes”, the OFF time is indicated. If the
schedule number [1][2][3][4] is selected, the indication changes to set the schedule number shown in 2. If [S] is
selected, see the section on setting temperature shifts for details.
:
SET
1
SCHEDULE
ON
4
OFF
:
Do not turn the air louver by hand. The louver mechanism may be damaged
if moved (in all units).
9
CAUTION
Wall-mounted type (RPK):
Adjust the vertical louvers by hand to discharge air in the required
direction.
Do not swing blade 1 to the left and blade 2 to the right of the vertical
louvering.
Automatic setting of the louver:
When the unit is not in operation, two air louvers stop automatically in the
closed position.
Horizontal louver
Vertical louver
Ceiling-mounted type (RPC):
The vertical louver consists of four sets of louvers. Adjust the vertical
louvers by hand to discharge air in the required direction.
8
NOTE:
The models which do not have a swing louver will not show the above indications
on the remote control. In this case, the louver must be adjusted manually.
One set
Vertical louver
Horizontal louver