21
P50XR01U/E P60XR01U/E
Reconfirm
ing
Vs and Va voltage
values
on
the
Power unit
P50XR01U/E and P60XR01U/E do not need adjustment. (Because P50XR01U/E and P60XR01U/E are self-adjust
ing
.)
However, Vs and Va voltages
require reconfirming
on
the
Power Unit.
This page explains
the
reconfirm procedure.
(1) Turn on the TV set and apply pre-heat run more than 1 min on burn-in screen.
(2) Receive full black pattern signal.
(or no video signal; but the power will be automatically turned off after a few seconds by
the
power save function.)
(3) Connect a voltmeter (which has a tolerance within 0.02V) to between Vs (or Va) test pin and GND test pin on the
power unit.
Adjustment Point: Refer to the figure below
Procedures
(1) Check Vs voltage and Va voltage at CN99 test pins.
Remarks
(1) Permissi
ble
level
s
of voltage in sufficient time of heat-run performed is as follows.
50V PDP model
60V PDP model
Reference Voltage
Vs
within
r
1.5V
within
r
3.0V
Va
within
r
1.0V
within
r
1.0V
Voltage described in the label on
the PDP panel
If it
i
s
difficult
to read the voltage value because of the wiring positions,
make a
note using
a marker
in a
visible space in
advance.
<LOT>N6
Vs=80.0V
Va=60.0V
Vw=140.0V Vx=60.0V
Label example
CN99
㧦
Vs/Va test pins
Ԙ
Va
ԙ
Vs
Ԛ
NC
ԛ
NC
Ԝ
GND
CN99
㧦
Vs/Va test pins
Ԙ
Va
ԙ
Vs
Ԛ
NC
ԛ
NC
Ԝ
GND
[60V PDP]
[50V PDP]
Summary of Contents for P50XR01E
Page 12: ...11 P50XR01U E P60XR01U E Remote control for r o f l e d o m E 1 0 R X XR01U model ...
Page 54: ...SM017 WIRING DIAGRAM 1 53 P50XR01U E P60XR01U E For P60XR01U E only ...
Page 55: ...SM017 WIRING DIAGRAM 2 54 P50XR01U E P60XR01U E For P60XR01U E ...
Page 59: ...SM017 PANEL MODULE 60PF2 FPF60C240135UB S2 58 P50XR01U E P60XR01U E For P60XR01U E ...