background image

Good combustion

Short supply of air

Oversupply of air

Oversupply of air

Damper

Damper location

Note

MAINTENANCE AND CARE

Note

Note

TROUBLESHOOTING

When fire extinction sound is loud, adjust air supply by turning Damper upward or downward.

If the burner and its surrounding parts get too dirty, incomplete combustion may result. Therefore, clean these 
parts carefully.

3. Air-Adjustment

For good flame, turn Damper upward and downward until the flame is in 

a  “good  combustion”  stated  as  shown  in  the  illustration.  For  the  center 
burner of MPH-310RI, there is no air-adjustment Damper.

1. Cleaning of the burner head and burner top surface. Each 

time liquid boils over and falls onto the burner, remove the 
burner head and clean it and its top surface with a brush.
When returning the cleaned burner head to the burner, make 
sure to set it correctly.

2.  Cleaning of the trivet & tray

Always keep the trivet & tray clean.

3. Cleaning of the electrodes of the igniter. If the electrodes are 

soiled, clean them with a dry  cloth as dust adhering these 
parts may prevent a good ignition.

Make sure that the burner body, burner head, trivet and other parts are set properly after cleaning.

If trouble occurs, fix it referring to the following table. If the problem still remains, or in case a serious malfunction, or if you 
are in doubt, take the table to the retailer from which you bought the unit, without trying to repair it yourself.

Trouble 

Cause

Remedial measure

Does not ignite

Smell of gas

Flame makes loud 
cracking sound while 
burning

- Main gas stopcock is not open.
- Air remains in the gas piping.
- Dirty electrode or insulator.
- Bent or crushed rubber hose.

- Make sure the ignition knob is at “OFF” position, then 
open the main gas cock fully.
- Repeat igniting operation until all air in the piping is 
completely purged.
- Clean it with a dry rag.
- Straighten gas hose.

- Cracks or holes in the rubber hose.
- Rubber hose not connected well.
- Failure or the gas table cock.

- Replace it with a new one.
- Connect gas hose surely.
- Ask the store for repairs.

- Air supply is not properly adjusted.
- Flame outlet of burner is closed.
- Burner is not fitted properly.
- Nozzle is clogged.

- Adjust it properly.
- Clean the clogged part.
- Fix burner body properly.
- Ask the store for repairs.

4

Summary of Contents for MPH-210RI

Page 1: ...OF GAS TABLE and 3 HOW TO USE n n n SPECIAL CAUTIONS AND SPECIFICATIONS 2 PREPARING THE UNIT FOR USE MAINTENANCE AND CARE and TROUBLESHOOTING 4 6 3 1 4 5 2 1 Top plate 2 Burner head big 5 Burner head small 6 Ignition ON OFF knob 3 Trivet tray big 4 Trivet tray small MPH 310RI 4 1 2 3 MPH 210RI 1 Top plate 2 Burner head big 3 Trivet tray big 4 Ignition ON OFF knob 1 IM MPH 210RI 310RI 16 07 INSTRUC...

Page 2: ...ivet top plate and other parts become hot during use Therefore touch no part of the gas table except the ON OFF knobs 11 Takenote that no boiling water shouldspill ontothe gas table stop surface 12 If you notice gas leakage stop using the gas table at once close the gas stopcock and open all windows and doors toallowthe gas to escape 13 In case of a gas leak NEVER turn on the gas table or turn on ...

Page 3: ...e securelywith ahose clamp Gas inlet pipe Rubber hose Hose clamp l Do not route the rubber hose under the gas table Do not place any objects that may easily be blown away by the wind on the gas table l l Never use one single rubber hose fortwogas tables Keep away flammable material liquidfrom the gas table l Makesurethat allknobs ofthe gas table atthe OFF position andopenfully the gas stopcockofga...

Page 4: ... dust adhering these parts maypreventa good ignition Make sure that the burner body burner head trivet and other parts are set properly after cleaning If trouble occurs fix it referring to the following table If the problem still remains or in case a serious malfunction or if you are in doubt take the table tothe retailerfrom whichyoubought the unit withouttryingto repairit yourself Trouble Cause ...