![Hitachi LQE010 Hardware Manual Download Page 50](http://html.mh-extra.com/html/hitachi/lqe010/lqe010_hardware-manual_140502050.webp)
6 MAINTENANCE
6-5
6.2.3 T/M2 (external loopback test)
Function
T/M2 connects the optical cables to the module (loopback connection) and performs loopback
test. It tests the module from the communication part to the connector.
Connecting optical fiber cables
As shown in Figure 6-1, connect the TX of the primary ring to the RX of the secondary ring and
the TX of the secondary ring to the RX of the primary ring.
Setting switches
Set the module No. switch to A or B and the CPL No. switch to /00.
When the module is operating normally
The LED (TX LED) for transmission and LED (RX LED) for reception start to blink. All other
LEDs are off.
When a communication error occurs
The error LED (ERR LED) comes on.
Figure 6-1 Connecting Optical Fiber Cables (T/M2)