5 Timing chart
KP-F80
8
Trigger B pulse
V.SYNC
Video output
5Vpp
Low: 0V
High: 5V
Reset control
Integration time
*1
Trigger pulse
3H~250ms
*1
1/3s
approx.
Special function of reset control Trigger
The camera shifts to the output of a normal mode (continuous output) when Trigger B signal passes about
1/3 seconds in the state of High.
(The image is output by inputting the Trigger at the VD cycle for this period.)
It returns to the Trigger mode if Trigger B signal becomes Low.
However, after becoming Low Trigger B, the period of 50ms becomes a Trigger signal input prohibition
period.