70
Input/Output Signals
1. Input signal conditions
1) Genlock input (MULTI connector)
・
VBS 1.0 Vp-p
±
3 dB or black burst/75 ohm or high (BNC)
(sync 0.3
±
0.1 Vp-p, burst 0.3
±
0.1 Vp-p)
・
HD/VD 2 to 5 Vp-p, negative (D-sub connector)
Note:
Genlock input and Sync output are selected by internal input/output switch.
2) External trigger input (MULTI connector)
Ext Trig Low 0 VDC, High 2 to 5 VDC
3) Serial data (REMOTE connector)
1.5 Vp-p
±
3 dB/High (when connected to RC-Z3, JU-C20, JU-Z2)
RS-232C level (when connected to personal computer)
Note:
Set internal switches according to connected equipment.
A level converter JU-C20 is required if controlling the camera from a personal computer via RS-
232C interface over a distance more than approx.15 meter.
2. Output signal ratings
1) Component video output (VIDEO, MULTI connector)
VBS 1.0 Vp-p/75 ohm
2) Y/C output (MULTI connector)
Y: 1.0 Vp-p/75 ohm
C: NTSC 0.286 Vp-p (burst)/75 ohm
PAL 0.3 Vp-p (burst)/75 ohm