H E A T P U M P W A T E R H E A T E R C O M P R E S S O R C R I T E R I A
热 泵 热 水 器 专 用 压 缩 机 使 用 基 准
PAGE:6/31
There should be superheated gas returned to the compressor under all normal operating conditions.
T a b l e 2
Item
Operating Envelope
Discharge pressure
MPa
3.13 {30.91}MAX
(condensing temperature
80°C )
(see graph 1)
Suction Pressure
MPa
0.139
~
0.95 {0.40~8.67}
(Evaporation Temperature
:-35℃
~2
5℃).
Compressor suction side can handle the same
maximum pressure as discharge side without
damage when compressor is not running.
Compressor case bottom
temp
99℃or below and 6 ℃ higher than condensing temperature,
(the time compressor case bottom temp 6 ℃below the condensing
temperature should be less than 5 minutes each time),
Requirement for high pressure ratio condition can be seen on page
28.
Motor winding temp
R.Voltage±10%: 120℃ MAX
Accumulator temp
Higher than outlet pipe of evaporator
Ambient temp
Meet for the condition of above mentioned motor winding
temp.