Chapter 6. Errors and error recovery
(5) Link area assignment duplication
Is the ERR LED on other
stations illuminated or blinking?
Set the value so that the link area
assignment is not duplicated.
Check to ascertain if the ERR LED on
other stations is illuminated or
blinking.
YES
NO
ERR LED
Flicker at 0.5 sec intervals
- Error information of own station : bit9 ON
Replace the module with a spare one,
if available.
Notify your local authorized distributor
of it.
(6) Outside the link area assignment range
ERR LED
Flicker at 0.5 sec intervals
- Error information of own station : bit9 ON
Replace the module with a spare one,
if available.
Notify your local authorized distributor
of it.
Is the ERR LED on Other
stations illuminated or blinking?
Correctly set the assignment range
between WL0000 to 03FF or WL1000
to WL13FF.
Check the link area assignment setting.
YES
NO
Note: As a check is run on link area assignments being outside of the permissible range in programming
devices when assignment is performed, this error will not occur under normal circumstances.
6-6