must first collect the write workload data under all workload conditions,
including peak write workload, and then measure and analyze the data. You
can use performance-monitoring software such as Hitachi Tuning Manager or
Hitachi Performance Monitor to collect the workload data.
Related topics
•
Planning physical paths on page 3-4
Fibre-Channel connections
Use short-wave (optical multi-mode) or long-wave (optical single-mode)
optical fiber cables to connect the storage systems at the primary and
secondary sites. The required cables and network relay devices differ
depending on the distance between the primary and secondary systems, as
described in the following table.
Distance between
storage systems
Cable type
Network relay device
Up to 1.5 km
Short wave (optical multi-
mode)
One or two switches are
required if the distance is
0.5 to 1.5 km.
1.5 to 10 km
Long wave (optical single-
mode)
Not required.
10 to 30 km
Long wave (optical single-
mode)
Up to two switches can be
used.
30 km or longer
Communication line
An authorized third-party
channel extender is
required.
No special settings are required for VSP G1000 if switches are used in a
Fibre-Channel environment.
Long-wave (optical single-mode) cables can be used for direct connection at a
maximum distance of 10 km. The maximum distance that might result in the
best performance differs depending on the link speed, as shown in the
following table:
Link speed
Maximum distance for best
performance
1 Gbps
10 km
2 Gbps
6 km
4 Gbps
3 km
8 Gbps
2 km
Related topics
•
Planning physical paths on page 3-4
Planning for global-active device
3-5
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...