data when you can no longer use a physical path between the server and a
storage system.
Before failure
After failure
Pair status and I/O
mode
Pair status and I/O
mode
Volume
accessible from
the server
Volume
with latest
data
P-VOL
S-VOL
P-VOL
S-VOL*
P-VOL
S-VOL
PAIR (Mirror
(RL))
PAIR (Mirror
(RL))
PAIR (Mirror
(RL))
PAIR (Mirror
(RL))
OK
OK
Both P-VOL
and S-VOL
COPY
(Mirror
(RL))
COPY
(Block)
COPY
(Mirror (RL))
COPY
(Block)
OK
NG
P-VOL
PSUS/PSUE
(Local)
SSUS/PSUE
(Block)
PSUS/PSUE
(Local)
SSUS/PSUE
(Block)
OK
NG
P-VOL
PSUS/PSUE
(Block)
SSWS
(Local)
PSUS/PSUE
(Block)
SSWS
(Local)
NG
OK
S-VOL
*If failures occur in all servers that access to the P-VOL or S-VOL, then you cannot
access either volumes.
SIM
•
Primary system: None
•
Secondary system: None
Recovery procedure
1
.
Recover the path between the server and the storage system.
2
.
Recover the path from the server to the pair volume.
Related topics
•
Pair condition before failure on page 6-7
Recovering from a path failure between the server and primary
system
The following figure shows the failure area and recovery when the path
between the server and primary storage system fails.
Disaster recovery of global-active device
6-9
Hitachi Virtual Storage Platform G1000 Global-Active Device User Guide
Summary of Contents for G1000
Page 8: ...Index viii Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 14: ...xiv Preface Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 238: ...9 18 Troubleshooting Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...
Page 245: ...Hitachi Virtual Storage Platform G1000 Global Active Device User Guide ...