![Hitachi FDV 16VB2 Technical Data And Service Manual Download Page 19](http://html.mh-extra.com/html/hitachi/fdv-16vb2/fdv-16vb2_technical-data-and-service-manual_141408019.webp)
--- 16 ---
8-6. Insulation Tests
On completion of disassembly and repair, measure the insulation resistance and the dielectric strength.
Insulation resistance: 7 M
Ω
or more with DC 500 V megohm tester
Dielectric strength:
AC 4,000 V/1 minute, with no abnormalities
• • •
220 V --- 240 V (and 110 V for U.K. products)
AC 2,500 V/1 minute, with no abnormalities
• • •
110 V --- 120 V
8-7. No-Load Current Values
After 30 minutes of no-load operation, current values should be as follows.
100 V
120 V
220 V
230 V
240 V
• • •
Less than 2 A
• • •
Less than 1 A