-9-
CAUTION: Be sure to apply TB1401 screw locking agent to the threads of the following screws and
bolts before tightening. Otherwise, the screw or bolt loosened by vibration may cause
damage to the tool body
.
Item No.
Part name
No.
used
Tightening torque
N•m
lbf-ft
[21]
Hex. Socket Hd. Bolt (W/Flange) M6 x 25
4
10 to 12
7.4 to 8.9
[50]
Hex. Hd. Tapping Screw D5 x 55
2
3.0 ± 0.5
2.2 ± 0.4
[65]
Tapping Screw (W/Flange) D5 x 20 (Black)
4
3.0 ± 0.5
2.2 ± 0.4
[75]
Hex. Socket Hd. Bolt (W/Flange) M5 x 16
2
6 to 8
4.4 to 5.9
[80]
Tapping Screw (W/Flange) D4 x 25 (Black)
2
2.0 ± 0.5
1.5 ± 0.4
[84]
Tapping Screw (W/Flange) D4 x 16
2
2.0 ± 0.5
1.5 ± 0.4
[92]
Seal Lock Hex. Socket Hd. Bolt M6 x 45
4
10 to 12
7.4 to 8.9
[109]
Seal Lock Hex. Socket Hd. Bolt M6 x 20
2
10 to 12
7.4 to 8.9
[110]
Hex. Socket Hd. Bolt (W/Flange) M5 x 18
4
8 to 10
5.9 to 7.4
[121]
Cap Screw
1
7 to 9
5.2 to 6.6
[127]
Hex. Socket Hd. Bolt (W/Flange) M5 x 12
1
4.0 ± 0.5
3.0 ± 0.4
After completing disassembly and repair, measure the insulation resistance and dielectric strength.
Insulation resistance: 7 M
Ω
or higher (as measured with a 500 VDC megohm tester)
Dielectric strength:
4,000 VAC/1 minute, with no abnormalities ----- 220 V – 240 V
(and 110 V for UK products)
2,500 VAC/1 minute, with no abnormalities ----- 110 V – 127 V
(except UK products)
After no-load operation for 30 minutes, the no-load current values should be as follows:
Voltage
110 V
120 V
127 V
220 V
230 V
240 V
Current max.
6.5 A
5.9 A
4.6 A
3.4 A
3.3 A
3.2 A
Tightening torque
No-load current value
Insulation test