– 25
–
CP-X325W
With the purse lock, Clamp the
Ballast lead and Sirocco fan lead
through the Ballast cover.
To Power unit
(Ballast)
Lamp lead
To PWB ass’y Main
E801,E802
Route the Sirocco
fan lead through
the opening.
Route the Sirocco
fan lead through
the inside of Duct
plate.
Route the Temperature switch
lead through the opening in
the Ballast cover
Hook the lead of Power unit
(Ballast) at the claw.
Do not put the lead on the
transformer of Power unit.
To PWB ass’y Main
E803,E807
CN1
Trans
Claw
Lead of Power unit (Ballast)
PAS1
CN101
Route the earth lead
of Optical unit through
the inside of Duct plate
and Optical unit.
Ballast cover
Exhaust fan
To Power unit (circuit)
CN104
Panel B
Sirocco fan
Lamp
Sirocco fan
Panel R
Sirocco fan
Panel G
Sirocco fan
FOOT HOLDER
Duct plate
Upper view (Removed PWB ass'y Main)
TAPE1
Folding part of the lead fixed not
to pass under the PWB ass’y Main.
PWB ass’y Main
Ballast cover
Folding part
Insert a CN101
before the Optical
unit installation.
Route the Temperature switch
lead through the opening in
the Exhaust fan.
Temperature
switch