background image

FEATURES ......................................................................................................

I - 1

CAUTIONS .....................................................................................................

1-2 

INSTALLATION ..............................................................................................

l - 6  

STANDARD SETTINGS.. ...............................................................................

1  7

OPERATION.. .................................................................................................

l - 8

AUTOMATIC SIGNAL CHECK.. ...................................................................

 

POWER MANAGEMENT SYSTEM.. ............................................................

PLUG   PLAY.. .............................................................................................

1   11

SPECIFICATIONS.. . . . ...................................................................................

The following features are provided by the Colour Monitor.

Sharpest Focus and Highest Contrast

Flat screen Enhanced Dot Pitch (EDP) CRT with FS double focus and AR-ASC coating

gives the sharpest focus and highest contrast to minimise eye fatigue.

Wide-range Multi-Scanning

Automatic scanning and automatic adjustment to conform with a wide range of scanning
frequencies and user requirements.

Digital Picture Control Function

Position, size, pincushion, trapezoid, parallelogram, pin balance and rotation are

adjustable by digital controls.

Geometry setting can be stored for different 

 frequencies. Microprocessor-based

preset functions can store 26 sets of geometry settings including the standard factory

settings.

Digital 

Colour Control 

Function

Red, green, and blue colour balance is adjustable by digital control.

An adjusted colour setting can be stored and recalled by the colour select button.

Moire Reduction

This monitor has horizontal and vertical moire reduction function.

Power Saving System

The Environmental Protection Agency (EPA) has established a voluntary program by
which manufacturers enable computer products to go into low power states while not

being used. This monitor has a low power “sleep” mode, which is compliant with the EPA
requirements for the 

 

 

program, and will assist you in conserving energy.

Please refer to the section of “POWER SAVING SYSTEM” for details.

An On Screen Display function that allows direct access to

 

adjust all operations from the front panel.

PLUG   PLAY

This 

monitor is VESA 

 compliant when used with a

computer compliant with VESA DDC (Display Data Channel).

l - l

Summary of Contents for CM650ET

Page 1: ...ANUAL FOR FUTURE REFERENCE v i For future reference record the serial number of your colour monitor SERIAL No The serial number is located on the rear of the monitor This monitor is ENERGY STAR compliant when used with a computer equipped with VESA DPMS The ENERGY STAR emblem does not represent EPA endorsement of any product or service As an ENERGY STAR Partner Hitachi Ltd has determined that this...

Page 2: ...tenen Irrtumer GESCHijTZTE WARENZEICHEN VGA ist ein eingetragenes Warenzeichen der International Business Machines Corporation VESA ist ein Warenzeichen der Video Electronics Standard Association einer Organisation ohne Erwerbscharakter ENERGY STAR ist ein Warenzeichen der Environmental Protection Agency EPA NOTA La information contenida en este manual esta sujeta a cambios sin previo aviso El fab...

Page 3: ...g continuously and thereby consumes a lot of energy What does labellmg involve This product meets the requirements for the TCO 99 scheme which provides for international and environmental Iabelling of personal computers The labelling scheme was developed as a joint effort by the TCO The Swedish Confederation of Professional Employees Svenska Nahtrskyddsforeningen The Swedish Society for Nature Con...

Page 4: ...ed circuit boards since no substitutes are available Cadmium Cadmium is present in rechargeable batteries and in the colour generating layers of certain computer displays Cadmium damages the nervous system and is toxic in high doses The relevant TCO 99 requirement states that batteries the colour generating layers of display screens and the electrical or electronics components must not contain any...

Page 5: ...ions can store 26 sets of geometry settings including the standard factory settings Digital Colour Control Function Red green and blue colour balance is adjustable by digital control An adjusted colour setting can be stored and recalled by the colour select button Moire Reduction This monitor has horizontal and vertical moire reduction function Power Saving System The Environmental Protection Agen...

Page 6: ... colours or distortion of the displayed pattern n BE CAREFUL OF GENERATED MAGNETISM After the power has been turned on or DEGAUSS button has been pressed the CRT is demagnetised for approximately 10 seconds This generates a strong magnetic field around the front cover which may affect the data stored on magnetic tape or disks near the front cover Place such magnetic recording equipment and tapes d...

Page 7: ...into a power point of the correct voltage check that the connection portion of the power cord is clean with no dust Then insert the plug of power cord to a power point firmly otherwise it may cause electrical shock or fire I REMOVE THE POWER CORD FOR COMPLETE SEPARATION For complete separation from the power source remove the power cord from the monitor or from the wall outlet n AVOID FREQUENT POW...

Page 8: ...d 2 Video inputs The input signal amplitude must not exceed the specified level CAUTION Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Declaration of Conformity According to 47CFR Part 2 and 15 for Class B Personal Computers and Peripherals and I or CPU Boards and Power Supplies used with Class B Pers...

Page 9: ...ed extension lead or consult your dealer Should it be necessary to change the mains plugs this must be carried out by a competent person preferably a qualified electrician If there is no alternative to cutting off the mains plug ensure that you dispose of it immediately having first removed the fuse to avoid a possible shock hazard by inadvertent connection to the mains supply WARNING THIS EQUIPME...

Page 10: ... of the country in which you are using the monitor Insert the connector of a power cord to the AC Inlet of the monitor Insert the plug of the power cord to a power point of the correct voltage 3 Signal Cable Connection Insert the Signal Input Connector of the monitor to the host computer with attention to it s suitability and secure the screws on the connector shell firmly D Sub Mini 1 B pin Conne...

Page 11: ...horizontal frequency Horizontal front porch should be more than 0 1 vs Horizontal sync width should be within 1 O 3 8 l Horizontal back porch should be more than 1 2 ps Horizontal blanking width should be more than 3 5 ps for 45 kHz 69 kHz horizontal frequency Horizontal front porch should be more than 0 1 vs Horizontal sync width should be within 1 O 3 0 ps Horizontal back porch should be more th...

Page 12: ...connection and the input sync signal are correct CONTROL 0 Press the Status switch The On Screen Display function of EasyMenu then shows the selected function its condition the function menu and the input signal frequencies n You can select the EasyMenu language Use the function LANGUAGE SELECT To select the function use the Function m switches To execute the selected function use the Adjust Switc...

Page 13: ... or Red the upper limit it makes the reaches the upper limit it Blue and Red weaker make the Green weaker B makes the Red and Green makes the Blue stronger stronger When the Blue reaches the When the Red or Green upper limit it makes the reaches the upper limit it Red and Green weaker make the Blue weaker l 9 ...

Page 14: ...NOL Spanish 1 1 DEUTSCH German ITALIAN0 Italian 1 1 ENGLISH FRANCAIS French POWER disables OFF the Power enables ON the Power m MANAGEMENT Saving System Saving Systems Refer to Page l l 1 Refer to Page l l 1 POWER MANAGEMENT POWER MANAGEMENT SYSTEM SYSTEM SJEJ AUTO SAVE disables OFF the Auto enables ON the Auto Save function Save function Refer to Page l 8 Refer to Page l 8 SAVE SAVE 9 DEGAUSS deg...

Page 15: ...ystem is effective only when used with VESA DPMS compliant PC or Video Card APM State Signal Requirement Monitor Action Power Consumption Power LED Standby H Sync OFF Switches to 15W max Orange Suspend VSync OFF saving mode 15W max Orange Off H Sync OFF and screen darkens 3W max Orange V Sync OFF NOTE Once the monitor receives the first signal from the PC and initiate the power management system T...

Page 16: ...Horizontal 31 69 kHz Vertical 50 130Hz Horizontal 1280 dots max Vertical 1024 lines max 110 MHz typical 16 0 inches 406 mm diagonal typical Horizontal 326 mm typical Vertical 245 mm typical 9300K Standard colour balance 9300K 6500K Standard colour balance 6500K USER User defined 30 minutes to reach optimum performance level AC 100 240 V automatically selected 50 60 Hz 2 5 A max Power Consumption 1...