www.hitachi.com
BladeSymphony 1000 Architecture
White Paper
41
SVP manages the entire BladeSymphony 1000 device. It also provides a user interface for
management via the SVP console. SVP provides the following functions:
• Module configuration management (module type, installation location, etc.) within a server chassis
• Monitoring and controlling of modules installed on the server chassis (power control, failure
monitoring and partition control)
• Monitoring and controlling of the environment (temperature monitoring, controlling fan RPM)
Table 12: Switch & Management Module components
Component
Manufacturer
Quantity
Description
Microproces-
sor
Hitachi
1
RTC
Epson
1
Battery backed-up
FPGA
Xilinx
1
SDRAM
-
128 MB
ECC
Flash ROM
-
16 MB
Stores the OS image
NV SRAM
-
1 MB
Battery backed up SRAM. Saves system
configuration information and fault logs
Compact flash
-
128 MB,
512 MB
Backs up the SAL and BMC firmware
Ether switch
Broadcom
2
Connect the management LAN of each
server blade
Gigabit Ether
switch
Broadcom
1
PHY chips for External ports 10BASE-T/
100BASETx/1000BASE-T Auto Negotia-
tion, Auto MDIX
Gigabit Ether-
net PHY
Broadcom
1
Converts the SerDes output from each
server blade into 1000Base-T.
SVP-LAN0
-
1
LAN port for connecting the system console.
Exclusively for maintenance personnel.
SVP-SAN1
-
1
LAN port for connecting the system console.
Always connected to the maintenance LAN
for notification by mail.
Maintenance
-
1
COM port for connecting the system con-
sole. Exclusively for maintenance personnel.
GBLAN0-3
-
4
10BASE-T/100BASE-Tx/1000BASE-T Ether
port
Pwrctrl
-
1
Not supported