background image

Summary of Contents for 3700

Page 1: ...n or other microcomputers Hitachi CD controller board Hitachi 3700 CD drive Do not install the Hitachi 3700 CD drive inside a workstation Install the Hitachi 3700 CD drive in the external cabinet provided by OCLC The first drive you purchase arrives installed in a custom cabinet Be careful to read and perform each step of these procedures If you damage the workstation or any upgrade components you...

Page 2: ...r to your workstation and unplug it 2 3 4 5 If you do not turn off and unplug the workstation you can electro cute yourself If you have a CD and or CD drive case attached to your worksta tion do not remove the cable that connects your CD drive and or CD drive case to your workstation until step 9 of this section Use the small flathead screwdriver to disconnect the monitor cable and other cables as...

Page 3: ...ddress when you install a CD controller board To change the OCLC l 0 Board address follow the steps in section 3 1 After you reset the OCLC I 0 Board s synchronous port address per form the following steps Install the CD controller board section 3 2 Install a Hitachi 3700 CD drive in a case section 3 3 Replace the system unit cover section 4 Attach cables and power cords section 5 Run diagnostics ...

Page 4: ...hes do not reset the 1 0 Board s synchro nous port address Set the CD controller address to 200H in sec tion 3 2 step 3 5 Reinstall the OCLC 1 0 Board in the same slot you removed it from see this subsection step 1 If you are installing the OCLC I 0 Board in an OCLC Workstation complete the following In an M300 Workstation attach the ribbon cable to the connec tor at the top of the board Grasp the...

Page 5: ...0 0 0 0 0 0 0 0 0 0 I uoooouoouo o ooouoo nu on DD D D L___Pin S chP11 my W o m ___ __c m m J 1 0 Address Pin Switch P2 Connect Data ready Interrupt Signal Fig 1 Jumper Settings on the TCD IFIB Controller Board 4 Make sure the jumper block on the IRQ selection panel at the bot tom center of the controller board is placed on S2 which is the first jumper on the left 5 Install the CD controller in th...

Page 6: ... the CD drive case Lift the cover off the CD drive case 4 Remove the front plastic panel plate where the new CD drive will be housed by pushing against the center of the plate with your fin ger from inside the case 5 Check the drive select settings located on the back of the CD drive The drive select settings determine a unique drive address for each of the eight possible drives Do not duplicate d...

Page 7: ...em with the small Phillips head screwdriver It is easier to replace the CD drive cover if you start all the screws and then go back and tighten them Go to section 4 to replace the system unit cover and section 5 to at tach the cables After you complete these steps run diagnostics section 6 add SETVER to the CONFIG SYS file section 7 install MS DOS CD ROM Extensions software section 8 and reconfigu...

Page 8: ... other end to either port on the new CD unit Data cable Usually attach to the OCLC 1 0 Board if it is the last workstation in a chain The exception is the M300 Workstation where you attach the data cable to the DATA SET port on the OCLC Interface Panel sometimes called the dog house Y cable Use with workstations in a dedicated line chain At tach to the ports of the OCLC 1 0 Boards in every worksta...

Page 9: ...A CKCD and press Enter The introductory screen appears and confirms that you are using Check CD Program 3 00 CKCD EXE VER 3 00 If the VER number is not 3 00 contact OCLC User Network Support and request Check CD Program 3 00 4 Press the space bar to continue The controller address menu appears see fig 3 If your Hitachi controller board has BASE ADDRESS selection juMpers indicate uhich addresses ar...

Page 10: ...s When an attached CD drive receives an error message go to section 10 to cor rect the error and then rerun Check CD Program 3 00 To print screen messages press Ctrl Print Screen with a printer connected and ready to print before you begin Press Ctrl Print Screen again when you finish Drive 0 see fig 4 working properly as indicated by the No Er ror messages If you do not receive error messages for...

Page 11: ...TED Reaet lln Seek Error S ctkln Seek Errnr Reed na S k Error DRIVE 7 SELtcTEO fteaet tlnc Seek Error Seekln Seek Error Jleedl nc Seek Error Drives 7 and 8 are not installed Fig 4 Example of Output from the Check CD Program 3 00 Drives 7 and 8 see fig 4 displayed Seek Error messages Seek Error messages are normal for drives that are not installed If you receive this message for an uninstalled driv...

Page 12: ...DOS CD ROM Extensions diskette If you mistakenly start the Setup Program on a diskette drive while operating from a different default drive by typing a setup as a single command in steps 3 and 4 you may get a long list of SYS files that the Setup Program asks if you want to install The title screen displays and the program tells you The following CD ROM device drivers were found HITACHIA SYS size ...

Page 13: ...X EXE file in the root directory of your hard disk drive The program responds Installing file MSCDEX EXE Copying file MSCDEX EXE to c MSCDEX EXE Done The program asks Would you like to continue the setup procedure Y or N 10 If you are using OCLC DiscLit press Y for yes to update the existing AUTOEXEC BAT and CONFIG SYS files with current pa rameters including the number of CD drives attached The p...

Page 14: ...er 4 At the next menu use the up down arrow keys to highlight 1 0 Board Address and press Enter 5 Type the correct alternate address 210 for the OCLC 1 0 Board and press Enter 6 Exit from the configuration program by pressing Esc until you see the main menu screen 7 Press Ait X to exit from the Setup program When the system asks if you want to save the changes to the Setup program press Y for yes ...

Page 15: ...eir sockets 2 Verify that the DIP switch settings on the OCLC I 0 Board are cor rectly set 3 Verify that the I 0 Board synchronous port address is set correctly in PASSPORT Software If you use an M300 I 0 Board without DIP switches the ad dress should be 300 If you use an l 0 Board other than an M300 I 0 Board without DIP switches the address should be 210 4 If one of the following error condition...

Page 16: ...raded system 6 Remove any user installed modifications for example an internal modem that may have been added to your workstation but are not part of this CD drive installation 7 Review installation procedures and rerun the diagnostic procedures 8 If you cannot resolve the problems call OCLC User Network Sup port Call OCLC User Network Support UNS to report that you have installed your CD drive Fa...