41
32LD7200 (PW2L)
Code
stored up in
failure history
Self checking
item
Problem Phenomenon
Cause
C10
No sync. (Snow noise)
OSD of “ ! Check Antenna ”
appears.
No connection of ANT cable
Preset tuning is not yet
H11
Tuner problem
Cannot receive the main
signal from antenna
Communication error of U101
H15
Composite
video
SW
IC
problem
Cannot receive picture and
audio
Cannot change input mode
Communication error of I201
H16
Component video SW IC
problem
No component picture
Cannot change input mode
Communication error of I202
H31
Color
demodulator
IC
problem
Abnormal color
Dark picture
Communication error of I501
H32
Sync.
separator
IC
problem
Unsynchronized picture
Communication error of I601
H33
3D Y/C separator IC
problem
Abnormal color
Dark picture / No picture
Communication error of I302
F63
I
2
C-bus latch problem
Cannot store setting data
(Ex. Channel, Volume etc.)
SCL3/SDA3 latched up
Latest error code
Diagnosis
H11: OK H15: OK
H16: OK H31: OK
H32: OK H33: OK
F63 F63 - - - - - - - - -
Self check result area
Failure history area
Check result
Check item
[OSD]
Signal circuit self-diagnosis function
This function is for the failure of the signal circuit, for example the phenomenon as below:
"Sometimes power turns off abnormally." "Sometimes picture disappears abnormally."
To enter to this Self-Diagnosis mode, follow the next steps:
Preparation:
1) The Power Cord should be connected to AC line and the Main Power switch should be turned on.
2) Turn the power off by the SUB-POWER(
) button of the monitor or the remote control.
Procedure:
1) Press the SUB-POWER(
) button and button on the center of the upper of the monitor at the same time,
and keep it for more than 5 seconds after the power turned on.
2) The monitor will be turned on, and it will display On-Screen Display of the Self-check result and the failure history as below.
3) Any operation would cancel the Self -Diagnosis mode.
4) The following table shows the OSD symbols and contents of failure PWB in which failure most probably would
be allocated according to the number of blinks.
If you clear history of failure, make FACTORY RESET: enter the factory setting mode; press the SUB-POWER(
)
button, INPUT SELECT(
) button and button on the center of the upper of the monitor at the same time. And
keep it for more than 5 seconds after the power turned on.
8. Seif-Diagnosis Function
Summary of Contents for 32LD7200
Page 10: ...9 32LD7200 PW2L Block diagram ...
Page 12: ...11 32LD7200 PW2L Service adjustment items by I2C bus control MAIN Part ...
Page 13: ...12 32LD7200 PW2L ...
Page 14: ...13 32LD7200 PW2L ...
Page 15: ...14 32LD7200 PW2L ...
Page 16: ...15 32LD7200 PW2L ...
Page 17: ...16 32LD7200 PW2L ...
Page 18: ...17 32LD7200 PW2L ...
Page 19: ...18 32LD7200 PW2L ...
Page 20: ...19 32LD7200 PW2L ...
Page 21: ...20 32LD7200 PW2L ...
Page 22: ...21 32LD7200 PW2L ...
Page 24: ...23 32LD7200 PW2L ...
Page 25: ...24 32LD7200 PW2L Service adjustment items by I2C bus control SUB adjust menu ...
Page 26: ...25 32LD7200 PW2L 10 ...
Page 27: ...26 32LD7200 PW2L ...
Page 28: ...27 32LD7200 PW2L ...
Page 31: ...30 32LD7200 PW2L 3 4 5 ...
Page 32: ...31 32LD7200 PW2L ...
Page 33: ...32 32LD7200 PW2L 22 ...
Page 44: ...43 32LD7200 PW2L Block diagram 2 2 ...
Page 45: ...44 32LD7200 PW2L 10 Disassembly diagram PC ABS ABS ABS ...
Page 49: ...THE UPDATED PARTS LIST FOR THIS MODEL IS AVAILABLE ON ESTA ...
Page 50: ...49 32LD7200 PW2L 12 Connection diagram ...
Page 53: ...HDMI PCB 39012588011 Formatter PCB 39012588006 ...
Page 54: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A VIDEO board 1 PW2L ...
Page 55: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A VIDEO board 2 PW2L ...
Page 56: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A VIDEO board 3 PW2L ...
Page 57: ...1 2 3 4 5 6 6 1 2 3 4 5 D G F E C B A VIDEO board 4 PW2L ...