English
37
6. Replacing carbon brushes
Take out the carbon brush by first removing the
brush cap and then hooking the protrusion of the
carbon brush
R
with a slotted head screw driver,
etc., as shown in Fig. 15.
When installing the carbon brush, choose the direction
so that the nail of the carbon brush
Q
agrees with the
contact portion outside the brush tube
S
. Then push
it in with a finger as illustrated in Fig. 16. Lastly,
install the brush cap.
CAUTION
Be absolutely sure to insert the nail of the carbon
brush into the contact portion outside the brush tube.
(You can insert whichever one of the two nails
provided.)
Caution must be exercised since any error in this
operation can result in the deformed nail of the carbon
brush and may cause motor trouble at an early stage.
7
Cleaning of the outside
When the impact driver and impact wrench are
stained, wipe with a soft dry cloth or a cloth moistened
with soapy water. Do not use chloric solvents, gasoline
or paint thinner, as they melt plastics.
8. Storage
Store the impact driver and impact wrench in a place
in which the temperature is less than 40°C, and out of
reach of children.
9. Service parts list
CAUTION
Repair, modification and inspection of Hitachi Power
Tools must be carried out by a Hitachi Authorized
Service Center.
This Parts List will be helpful if presented with the
tool to the Hitachi Authorized Service Center when
requesting repair or other maintenance.
In the operation and maintenance of power tools, the
safety regulations and standards prescribed in each
country must be observed.
MODIFICATIONS
Hitachi Power Tools are constantly being improved
and modified to incorporate the latest technological
advancements.
Accordingly, some parts may be changed without
prior notice.
NOTE
Due to HITACHI’s continuing program of research and
development, the specifications herein are subject to
change without prior notice.
Information concerning airborne noise and vibration
The measured values were determined according to
EN60745 and declared in accordance with ISO 4871.
Measured A-weighted sound power level:
100dB (WH14DL)
101dB (WR14DL, WH18DL)
103dB (WR18DL)
Measured A-weighted sound pressure level:
89dB (WH14DL)
90dB (WR14DL, WH18DL)
92dB (WR18DL)
Uncertainty KpA:3dB(A)
Wear ear protection.
The typical weighted root mean square acceleration
value:
9.1 m/s
2
(WH14DL)
7.4 m/s
2
(WR14DL)
9.2 m/s
2
(WH18DL)
6.3 m/s
2
(WR18DL)