Troubleshooting
Function of fault alarm and flash
E1
E2
E3
E4
E5
E6
E7
Exceptional
phenomenons
Cause
Sensor of water
lever series
No indication
in controller
The power plug is not plugged tight,
the Power switch is not switched
No display
No display
Re-plug the power plug,
press”POWER”button
Power socket no electricity or
fuse disconnection
Check the power socket or fuse
After the failure Of electricity
supply, it need to re-operation
After the electricity, Wash Rinse
Spin Normal four indicator lights up
Overhigh voltage or low voltage Low voltage no display, overhigh
voltage may cause the fuse damaged
Pull the plug, use after the
voltage return to normal
Enter water
failure
Have not open the tap, stop water, low water pressure,
water have not reach the set water level after 20minutes
Open the tap, Clean the netting according to
the method of “Cleaning the water inlet”
Drain failure
The drain house is placed too high or have not lay down
the drian hose. The drain hose is wrung or jammed.
Check the drain hose, lay the drain hose lowly, press
“Start/Pause” button after checking. Open the machine
cover and close the machine cover for alarm free
Open abnormal
Safety lid is open
Closed the lid
Touch the
shell during
the spinning
Cloth are uneven in tub causes its unbalance and rub
the shell. Washing machine will adjust itself. After twice
adjustment,if it still in unbalance,it will Be warning.
Open the lid, put clothes well, close the lid
Overhigh
water level
Water level up on the highest safety water level
PCB can Auto-precess
Sensor of water
lever abnormal
Stage frequency less than high water level limit
or exceed than low water level limit, will shows
sensor of water lever error alarm
Please ask professional person to check
Pause
abnormal
Pause time exceed 10 minutes
Please press the “start” button
Solution
After the electricity,
please re-operation
Note :After checking the above points, there is still an exception.
Please pull off the power plug and contact the distributor as soon
as possible.
Sensor of
waterTemerature
abnormal
Sensor of water temperature open/short circuit
E8
Restore normal or automatically
switch to cold water
Super high
water temperature
Water temperature is more than 93 degrees
Wait for water temperature to cool or switched
to hot program washing or shutdown
E0
Heating abnormal
Continuous heating for 30 minutes, the temperature rise is
less than 2 degrees
Switched to hot program washing or shutdown
EC
Lid lock abnormal
Continuous action ,can not be locked or cannot be opened
Restart
F1
Communication
abnormal
The display board and the drive board are not connected well
Call to service center for help
CE
9
Summary of Contents for XQB30-M328H
Page 1: ...MODEL XQB30 M328H...
Page 8: ...Safety and Precautions 7...
Page 9: ...Safety and Precautions 8...