Service manual
Refrigerator (freezer)
Single door serial
7
NO COOLING
The compressor
runs
Frost doesn’t form at the
evaporator when operating set for
more than 30min
Refrigerant leaks poor
compressing
Repair the compressor
Poor running of
the compressor
Measure the starting voltage
Low voltage
Increase the voltage
Check if the current flows at the
contacting point of the starting
system
Poor contacting point
and broken
Replace the device
Check if the current flowing of the
sub coil of the compressor
Shorted
Replace the
compressor
Is the current amount of the
electric components normal
Replace the
compressor
The coil of the
compressor motor is
worn out
The compressor
doesn’t run
Check if the current flows at the
contacting point of the thermostat
Poor contacting point
Replace the thermostat
Check the current flowing of
starting system
Shorted broken
Replace the device
Check if the current flows at the
main coil of the compressor
Coil shorted
Replace the
compressor
Check the components on the main
circuit
Replace the
components