NO COOLING 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 

The compressor 
runs 

Frost doesn’t form at the 
evaporator when operating set for 
more than 30min

Refrigerant leaks poor 
compressing 

Repair the compressor

Poor running of 
the compressor 

Measure the starting voltage

Low voltage 

Increase the voltage 

Check if the current flows at the 
contacting point of the starting 
system 

Poor contacting point 
and broken   

Replace the device

Check if the current flowing of the 
sub coil of the compressor 

Shorted 

Replace the 
compressor 

Is the current amount of the 
electric  components normal 

Replace the 
compressor 

The coil of the 
compressor motor is 
worn out 

The compressor 
doesn’t run 

Check if the current flows at the 
contacting point of the thermostat

Poor contacting point   

Replace the thermostat 

Check the current flowing of 
starting system 

Shorted broken 

Replace the device   

Check if the current flows at the 
main coil of the compressor 

Coil shorted   

Replace the 
compressor 

Check the components on the main 
circuit  

Replace the 
components  

Summary of Contents for RS-11DC4S

Page 1: ...Service manual Refrigerator freezer Single door serial 1 Refrigerator service manual Single door serial MODEL RS 11DC4S BD 85 HC E ...

Page 2: ...e door serial 2 Content 1 Safety precautions 3 3 2 Specification 4 4 3 Refrigeration system diagram 5 5 4 Circuit diagram 5 5 5 Maintenance service and Troubleshooting 6 9 6 Quality information report 10 10 7 Exploded view and part list 11 13 ...

Page 3: ...ck regular current voltage and capacity 5 Don t touch metal products in the freezer with wet hands this may cause frostbite 6 Prevent water from following onto electric elements in the mechanical parts 7 When tilting the refrigerator especially the thin plates ex Glass shelf or books 8 When servicing the evaporator wear cotton gloves This is to prevent injuries from the sharp evaporator fins 9 Lea...

Page 4: ... Recessed Grip Recessed or grip Lock Optional Refrigerant R600a General Features Foam Blowing Agent Cyclopentane Shelf Material No N A Door Basket N A Interior Lamp N A Vegetable Crisper N A Vegetable Crisper Cover N A Refrigerator Compartment Can storage Dispenser N A Star Rating 4 Ice Maker Automatic Twist Normal Normal Shelf Material No N A Drawer Transparent PS 4 Freezer Compartment Door Baske...

Page 5: ...ator is just powered on The refrigerant flows in the sequence Compressor Condenser Dry filter Capillary tube Evaporator 4 Circuit diagram The thermostat directly controls the start and stop of compressor and hence the refrigerator temperature The door switch directly controls the start and stop of the lamp ...

Page 6: ...r in a refrigerating system when during the filling phase vacuum is not effected or it is not adequately done Group must be drained and subsequently refilled after carefully creating vacuum Blocked capillary Because of the lack of circulation Freon in the system there is no frosting of the evaporator while a slight overheating of the first spiral of the condenser is noted Eventual impurities conta...

Page 7: ...n Replace the device Check if the current flowing of the sub coil of the compressor Shorted Replace the compressor Is the current amount of the electric components normal Replace the compressor The coil of the compressor motor is worn out The compressor doesn t run Check if the current flows at the contacting point of the thermostat Poor contacting point Replace the thermostat Check the current fl...

Page 8: ... and measure the voltage tween M and C of the compressor Advice the customer to use in the fixed The applied voltage is not in the range of rating voltage 10 1 2 4 2 3 3 NO NO YES Check the starting state Measure minimum starting voltage after checking steps1 3 above And measure the pressure balance of the PTC with the interval of more than Starts at the voltage of 85 below Normal Replace the PTC ...

Page 9: ...een NO 5 and 6 in the PTC with a multitester or Wheatstone bridge The value is in the range of 14 28 for the 22 Ω PTC Normal Check another electric component Separate the OLP from the compressor and check resistance value between two terminals of OLP with tester Check another electric components The value is 0 Abnormal Replace the PTC The value is Abnormal Replace the PTC Replace OLP ...

Page 10: ...sfactory products kindly please fill in the questionnaire attached below We shall strive for best to optimize our products based on your advices Customer name Purchasing Place Date No Model No Parts Name Problem Description Parts Photo Quantity Rate Serial No 1 2 3 Epidemic problem of a lot of products description please provide the photo of the damage parts Customer s advice Factory s response ...