![Hisense MSD6886 Service Manual Download Page 25](http://html1.mh-extra.com/html/hisense/msd6886/msd6886_service-manual_2138634025.webp)
- 25 -
c.
Close the OSD menu after 5 seconds.
d.
Restart the TV.
e Also the Keys information must been checked, if appear “NG”, then must rewrite key code.
4. Software Upgrading
4.1 USB Upgrade
Main software upgrade directly with USB
The main software can be upgraded with USB disk. It includes two modes: user mode
、
factory mode.
Take
HE55A7000EUWTS
for example.
4.1.1 TV in user mode
:
a.
Decompress
MICALIDVB6886
_pkg_YYYYMMDD.tar.gz (YYYYMMDD
is the year/month/day when the
software is being built, such as
MICALIDVB6886
_pkg_201801204.tar.gz) and rename to MstarUpgrade.bin ,
then copy the MstarUpgrade.bin
file to
the USB root directory. Please make sure there are no other “*.bin” files
in the root directory of USB disk .
b.
AC power off the TV, insert the USB disk, TV in standby status, next long press the “power key . If
“Loading
data……”
is shown on TV, it means TV successfully enters upgrading status..
c.
Waiting…… TV is trying to load the software and it will spend about 2 minutes. After that
“UPGRADING
SOFTWARE, PLEASE DO NOT TURN OFF”
will be displayed and upgrade process bar will indicate the
progress. It needs about s5 minutes to complete the whole software upgrade.
d.
After upgrade, TV can automatically reboot.
e.
Enter the Factory OSD Menu to check the main software version, and then choose “option”
“Clear All” to do
clean up.
4.1.2 TV in factory mode
:
a.
If TV is in Factory mode, only have difference from chapter 4.1.1 b. as following. others are same.
b.
TV is in factory mode, only AC power off TV and insert the USB disk, next AC power on, TV can identify
automatically to update, till call up
“Loading data……”
interface ,
update process bar is 1%.
4.1.3 If the above USB upgrade methods fail, you can rename the upgrade software to
MstarUpgrade.bin,next use serical
“
cu
”
to update
4.1.4 When upgrade successfully, We must ensure the TV mode of running correctly.
Paths: Factory---Design –Project ID
Once choose another TV mode ,must AC power off and power on the TV to reboot.
Summary of Contents for MSD6886
Page 2: ...2 REVISION HISTORY Version Revise content Reviser Date V1 00 First issued 2018 12 5...
Page 10: ...10 2 TV boards 2 1 Main board layout 2 1 1 The top of main board RSAG7 820 8698 ROH...
Page 11: ...11 MSD6886...
Page 17: ...17 3 Factory Service OSD Menu and Adjustment 3 1 Remote Control...
Page 19: ...19 3 3 Factory OSD Menu figure 1...
Page 26: ...26 Firgure 1 Loading data Firgure 1 Firgure 2 Upgrading software...
Page 35: ...35 Click Help Product Key enter security Click Flash Update Mode...