Hisense BD-262WY Service Manual Download Page 18

 

17 

(Many reasons might cause that cooling not enough good, as blow :) 

Reason 

analysis 

Solutions 

1) Leakage of Gas 

If some gas leaked unit will work not well. 
Phenomenon of failure: 
a. lower pressure of liquid cycle system 
b. high temperature of copper tube of 
discharging gas, hand feels very hot. 
C. much noise, sounds like “ZZZZZ”, comes 
from outlet of capillary. 
d. the temperature fell down very slowly. 

First find out the point of leaking on 
tube, and then sealed it, vacuuming 
it, finally recharge with Gas. 
Note: 
If you find oil on somewhere, it is 
possible that leakage point is there. 

2)

 

The quantity of Gas is 

too much 

If too much Gas was charged into the cycle 
system, the extra gas will occupy some space 
of evaporator, so that the area of heat 
exchange becomes less, unit will work not well. 
Phenomenon of failure: 
a, higher pressure of liquid cycle system than 
norm. 
b, higher temperature of condenser. 
c, larger electric current of compressor 
d, there maybe ice on the suction tube. 
e, when gas is too much, some gas liquid might 
goes back into compressor, compressor will be 
damaged by liquid. 

First stop unit for several minutes, 
and then open charging tube, 
discharge all of gas. Change a new 
filter, and then recharge gas, finally 
sealed the system. 
 

3) There is air in the 
liquid cycle system 

The air in system will cause lower efficiency of 
cooling. 
Phenomenon of failure: 
a, higher pressure of liquid cycle system than 
norm, but the pressure is not over the limit. 
b, higher temperature of discharging tube. 
C, much noise 

First stop unit for several minutes, 
and then open charging tube, 
discharge all of gas. Change a new 
filter, and then recharge gas, finally 
sealed the system. 

4)Low working 
efficiency of 
compressor 

General when a compressor works for many 
years, some parts of compressor were wear, so 
that compressor discharge less gas out, unit 
does not work strongly. 
Phenomenon of failure: 
a, lower pressure of discharging, check the 
pressure of system with pressure meter to see 
if it is normal. 
b, higher temperature of compressor surface. 
C, cut off the discharging tube, to see if you can 
block the gas coming out of the tube when 
compressor is working. 

Change a new compressor. 

5) There is something 
that blocked the liquid 
cycle system 

Some time there is something blocked the 
filter of liquid cycle system, so that unit is not 
cold. 
Phenomenon of failure: 
a, lower pressure of discharging 

Change a new filter 

Summary of Contents for BD-262WY

Page 1: ...Refrigerator Service manual NO FROST Model RS 34WC BD 262WY NOTE product specifications are subject to change...

Page 2: ...temperature sensor 8 The instruction of replacing evaporator temperature sensor and temperature fuse and heater 8 The instruction of replacing PTC Starting relay and Overload protector 9 The instructi...

Page 3: ...2 Circuit diagram...

Page 4: ...3 Cooling diagram...

Page 5: ...4 Display controls...

Page 6: ...5...

Page 7: ...6...

Page 8: ...instruction of replacing the main board and display board Unscrew the back cover screws Remove the electron box cover and replace the main board The instruction of of replacing fan motor Remove the wi...

Page 9: ...n motor The instruction of replacing temperature sensor Open air duct Board And take out sensor The instruction of replacing evaporator temperature sensor and temperature fuse and heater The instructi...

Page 10: ...lay and Overload protector 1 The location of the PTC Starting relay and Overload protector 2 Disconnect the connecting wire of the PTC Starting relay and Overload protector The instruction of replacin...

Page 11: ...10 The instruction of replacing Display board 1 The location of the display board 2 Unplug the display board wires and remove the screws fixing...

Page 12: ...11 Installing your new appliance...

Page 13: ...12...

Page 14: ...13...

Page 15: ...14...

Page 16: ...PCB 3 Change the display PCB 4 The freezer digital display window show EF 1 The Fan motor is open circuit or short circuit 2 The Fan motor is bad 3 The control PCB is bad 1 Using a Multimeter with the...

Page 17: ...3Whether the internal accessory of the refrigerator is in the right place 5 4Whether the water plate of compressor is fall from the unit 5 5 Does the tube of the refrigeration system bump each other...

Page 18: ...for several minutes and then open charging tube discharge all of gas Change a new filter and then recharge gas finally sealed the system 3 There is air in the liquid cycle system The air in system wi...

Page 19: ...The noise of liquid flow disappears The pressure of absorbing becomes negative The phenomenon above will appear again and again The way to check ice blocking Warm the capillary with a hot towel after...

Page 20: ...al of door is damaged Replace the gasket 4 Too much food in the refrigerator Please put the food properly 5 Wind door is broken Replace wind door 6 Fan motor is broken Replace fan motor NOTE Before do...

Reviews: