24
The ice on the evaporator defrosts
The pressure of absorbing becomes
negative.
Higher temperature of discharging
tube
The way to check offal blocking:
If you warm capillary with the way of
checking ice blocking, there is no
change. It must be offal blocking.
COMPRESSOR NEVER STOPS
:
Reason
Solutions
1)The setting temperature is not reasonable.
Readjust the temperature setting.
2) the sensor is bad.
Replace the sensor.
3)Seal of door is damaged.
Replace the gasket
4)Too much food in the refrigerator
Please put the food properly.
5)Wind door is broken.
Replace wind door.
6)Fan motor is broken.
Replace fan motor
■
NOTE:
●
Before doing these operations above, disconnect t
he main power supply. Failure to do so could result in
electrical shock or personal injury.
●