53
A
:
The accumulated time of defrosting is longer than 12 minutes (EEPROM setting value in the current
operating mode);
B
:
If the temperature of coiled pipe is equal to or higher than 14 degrees centigrade (EEPROM setting value
in the current operating mode);
Actions of exiting the defrosting state:
The compressor stops, and 50 seconds later the four-way valve opens, and another 10 seconds later the
compressor and outdoor fan restart and begin normal operation.
6. Electrical Characteristics
6-‐1. Print Circuit Board (Indoor & Outdoor)
Model
Indoor unit
Outdoor unit
AS-07UR4SYD
DB15
1550982
OU-PCB-SYD/SVE
AS-09UR4SYD
DB15
1550982
OU-PCB-SYD/SVE
AS-1
1
UR4SYD
DB15
1550982
OU-PCB-SYD/SVE
AS-18UR4SUA
DB5
1550982
1570567
AS-24UR4SFB
DB5
1564090
???????? +
1570567
AS-1
3
UR4S
V
D
DB5
1550982
OU-PCB-SYD/SVE
Summary of Contents for AS-07UR4SYDDB15