Installation Instructions
ML17H User Manual, 99164B, September 2021
13
3�
Cut a rectangular hole in the panel.
f
Cutout Dimensions (W x H) for the HIS-ML17:
406.9 mm x 323.1 mm (16.02" x 12.72"); ± 0.5 mm (0.020")
4� Clean and deburr the panel hole�
5�
Separate the rear collar from the monitor by removing the 12 nuts.
6�
Refer to the enclosure mounting diagram below.
7� Insert the unit into the front of the panel and re-attach the collar�
NOTE:
Contact Hope Industrial Systems if for any reason your application does
not allow for installation of the collar�
8�
Tighten all 12 nuts to a torque of 10-15 inch-pounds to ensure a watertight seal
between the bezel gasket on the monitor and the equipment panel. Go around all
nuts twice to ensure an even compression on gasket.
NOTE:
If a torque wrench is not available, tighten all nuts evenly until bezel sits
1.6 to 2.4 mm (1/16" to 3/32") off the front of the panel.