![Hirschmann SPIDER Premium Line User Manual Download Page 27](http://html1.mh-extra.com/html/hirschmann/spider-premium-line/spider-premium-line_user-manual_2138065027.webp)
Installation SPIDER-PL
Release 03 08/2016
27
4.5
Connecting the terminal block
The supply voltage can be connected redundantly. Both inputs are
uncoupled. There is no distributed load. With redundant supply, the power
supply unit with the higher output voltage supplies the device on its own. The
supply voltage is electrically isolated from the housing.
For the supply voltage to be connected, perform the following steps:
Remove the power connector from the device.
Connect the wires according to the pin assignment on the device with the
clamps.
Note:
With a non-redundant supply of the supply voltage, the device reports
the loss of a supply voltage. You can prevent this message by applying the
supply voltage via both inputs, or by changing the configuration.
WARNING
ELECTRIC SHOCK
Connect only a supply voltage that corresponds to the type plate of your
device.
Never insert sharp objects (small screwdrivers, wires, etc.) into the
connection terminals for electric conductors, and do not touch the terminals.
Observe the maximum values for the contact load of the signal contact.
Failure to follow these instructions can result in death, serious injury,
or equipment damage.
Figure
Pin
Function
1
+ 24 V DC
2
FAULT
3
0 V
4
0 V
5
FAULT
6
+ 24 V DC
+24 V
+24 V
0 V
0 V
Summary of Contents for SPIDER Premium Line