Programming Procedure
© PAT
Rev. C 06/15/00 // CSH
056-065 / 190005_c.doc
15
Step 3
The maximum boom length preset value is displayed, use the “UP” (12) and
“DOWN” (11) buttons to change the displayed value to your desired limit.
Push Button “OK” (10) for next step.
Step 4
Verification of the previously set values for maximum and minimum boom
length presets are displayed. If the value are incorrect press “OK” (10) button
and restart the limit preset procedure. Pressing “OK” will store the preset
values and return to the working screen.
4.3.2 Setting of Boom Angle Presets
Step 1
This message appears after pushing the “LIMIT” (8) button and pressing the
“DOWN” (11) button to scroll through the limits. To set a minimum and
maximum boom angle limit press the “OK” (10) button.
Step 2
The minimum boom angle preset value is displayed, use the “UP” (12) and
“DOWN” (11) buttons to change the displayed value to your desired limit.
Push Button “OK” (10) for next step.
Step 3
The maximum boom angle preset value is displayed, use the “UP” (12) and
“DOWN” (11) buttons to change the displayed value to your desired limit.
Push Button “OK” (10) for next step.
Step 4
Verification of the previously set values for maximum and minimum boom
angle presets are displayed. If the values are incorrect press “OK” (10) button
and restart the limit preset procedure. Pressing “OK” will store the preset
values and return to the working screen.
MAX. LIMIT: 90
USE
↑↓
OR OK
MAX. LIMIT: 90
MIN. LIMIT: 10
ANGLE LIMIT?
PUSH
↓
OR OK
MIN. LIMIT: -15
USE
↑↓
OR OK
MAX. LIMIT: 90
USE
↑↓
OR OK
MAX. LIMIT: 90
MIN. LIMIT: -15