Dimension drawings
Figure 1: Dimensions
EMC and immunity
EMC interference immunity
IEC/EN 61000-4-2
Electrostatic discharge
Contact discharge
Air discharge
6 kV
8 kV
IEC/EN 61000-4-3
Electromagnetic field
80 MHz ... 2700 MHz
20 V/m
IEC/EN 61000-4-4
Fast transients (burst)
AC/DC supply connection
Data line
2 kV
4 kV
IEC/EN 61000-4-5
Voltage surges
DC supply connection
Data line
line/line
line/ground
1 kV
2 kV
1 kV
IEC/EN 61000-4-6
Conducted disturbances
150 kHz ... 80 MHz
10 V
EN 61000-4-9
Pulse magnetic fields
300 A/m
EMC interference emission
EN 55022
Class A
Yes
52,8 mm 2.08 inch
171,8 mm
6.77 inch
183,8 mm
7.24 inch
188,5 mm 7.43 inch
120 mm 4.73 inch