MACH 4002
Release 1.0 10/05
35
Interfaces
EMV and stability
Network size
Interface
Design
MACH 4002
signal contact
4-pin pluggable terminal block
V.24 interface
1 x RJ11 socket
USB interface
to connect an AutoConfiguration Adapter
ACA 21-USB
EMV interference
proof
EN 61000-4-2
Discharge of static electricity
Contact discharge: test level 3
Air discharge: test level 3
6 kV
8 KV
EN 61000-4-3
Electromagnetic fields
Test level 3 (80 - 2000 MHz)
10 V/m
EN 61000-4-4
Fast transients (burst), test level 3, x
- Power line
- Data line
2 kV
4 kV
EN 61000-4-5
Surge voltage
- Power line, line/line: test level 2
- Power line, line/earth: test level 3
- Data line: test level 3
1 kV
2 kV
2 kV
EN 61000-4-6
Cable-based RF faults, test level 3
10 kHz - 150 kHz
150 kHz - 80 MHz
3 V
10 V
EN 61000-4-9
Impulse-shaped magnetic fields; test level 4
300 A/m
EMV emitted immunity
EN 55022
Class A
Yes
FCC 47 CFR Part 15
Class A
Yes
Germanischer Lloyd
Rules for Classification and Construction VI - 7 - 3
Part 1, Ed. 2001
Yes
Festigkeit
Vibration
IEC 60068-2-6 Test FC, testing level in line with IEC
61131-2
Yes
Germanischer Lloyd Guidelines for the Performance
of Type Tests Part 1
Yes
Shock
IEC 60068-2-27 Test Ea, testing level in line with IEC
61131-2
Yes
Length of a twisted pair segment
100 m approx.
cat5e cable with 1000BASE-TX
Table 1: TP port 10BASE-T / 100BASE-TX / 1000BASE-T
Summary of Contents for MACH 4002 48+4G
Page 40: ...40 MACH 4002 Release 1 0 10 05 ...