Diagnostics
[ Diagnostics > Status Configuration > Device Status ]
233
RM GUI GRS
Release
8.0
09/2019
6.1.1
Device Status
[ Diagnostics > Status Configuration > Device Status ]
The device status provides an overview of the overall condition of the device. Many process
visualization systems record the device status for a device in order to present its condition in
graphic form.
The device displays its current status as
error
or
ok
in the
Device status
frame. The device
determines this status from the individual monitoring results.
The device displays detected faults in the
Status
tab and also in the
Basic Settings > System
dialog,
Device Status
frame.
The dialog contains the following tabs:
[
Global
]
Device status
Device status
Displays the current status of the device. The device determines the status from the individual
monitored parameters.
Possible values:
error
The device displays this value to indicate a detected error in one of the monitored parameters.
ok
Traps
Send trap
Activates/deactivates the sending of SNMP traps when the device detects changes in the
monitored functions.
Possible values:
marked
The sending of SNMP traps is active.
If the device detects a change in the monitored functions, then the device sends an SNMP trap.
unmarked
(default setting)
The sending of SNMP traps is inactive.
The prerequisite for sending SNMP traps is that you enable the function in the
Diagnostics > Status
Configuration > Alarms (Traps)
dialog and specify at least 1 trap destination.
Summary of Contents for GREYHOUND GRS1020
Page 8: ......
Page 16: ......
Page 146: ......
Page 232: ......
Page 310: ......
Page 330: ......
Page 338: ...Readers Comments 337 RM GUI GRS Release 8 0 09 2019 ...
Page 339: ......
Page 340: ......
Page 350: ......
Page 354: ......
Page 617: ...Readers Comments 277 UM Config GRS Release 8 0 09 2019 ...
Page 618: ......
Page 619: ......