![Hirschmann GREYHOUND GMM 40 User Manual Download Page 17](http://html1.mh-extra.com/html/hirschmann/greyhound-gmm-40/greyhound-gmm-40_user-manual_2138093017.webp)
Installation GREYHOUND Switch
Release 01 04/2016
17
1.2.2
Power supply units
Item
Characteristic
Character
istic value
Description
1 ... 3
Product
GPS
GREYHOUND Power Supply Unit
4
Type
1
Standard
Power supply for
basic device
2
PoE(+)
Power supply for PoE(+)
3
PoE (+) basic
device
Power supply for basic
device and PoE(+)
5
(hyphen)
–
6
Rated voltage range
C
Rated voltage range DC
24 V ... 48 V
K
Rated voltage range DC
60 V ... 250 V
Rated voltage range AC
110 V ... 240 V
P
Rated voltage range DC
48 V (PoE) ... 54 V (PoE+)
7
Temperature range
S
Standard
+32 °F ... +140 °F
(0 °C ... +60 °C)
T
Extended
−
40 °F ... +158 °F
(
−
40 °C ... +70 °C)
E
Extended with
conformal coating
−
40 °F ... +158 °F
(
−
40 °C ... +70 °C)
8 ... 9
Certificates and
declarations
You will find detailed information on the certificates and
declarations applying to your device in a separate overview.
See “Assignment: application cases, certificates and
declarations, characteristic values” on page 19.
10 ... 11 Customer-specific
version
HH
Hirschmann
Summary of Contents for GREYHOUND GMM 40