![Hirschmann 943 686-003 Operating Instructions Manual Download Page 6](http://html1.mh-extra.com/html/hirschmann/943-686-003/943-686-003_operating-instructions-manual_2138084006.webp)
5. Technical data
General data
Operating voltage
NEC Class 2 power source 24 VDC (-25% +33%) safety extra-low voltage (SELV/PELV)
(redundant inputs decoupled), 5 A maximum
Buffer time
min. 10 ms at 24 VDC
Potential difference between input
Potential difference to input voltage, +24 VDC: 32 VDC
voltage and housing
Potential difference to input voltage, ground: -32 VDC
Current consumption at 24 VDC
7.0 W maximum
Overload current protection at input
non-changeable fuse
Dimensions W x H x D
47 mm x 135 mm x 111 mm
1.9 in x 5.3 in x 4.4 in
Weight
230 g
5.07 lb
Ambient temperature
0 ºC to + 60 ºC
32 ºF to 140 ºF
Storage temperature
- 20 ºC to + 80 ºC
-4 ºF to 176 ºF
Humidity up to 95% (non condensing)
Atmospheric pressure
min. 79 kPa
Protection type
IP 20
Radiated emission
CFR-47 Part 15 Class A,
Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1 EN 55022 Class A
Warning!
This is a Class A device. This equipment may cause radio interference if used in a
residential area. In this case the operator may be required to take appropriate measures.
Interference proof
Discharge of static electricity
Contact discharge
EN 61000-4-2 Test level 3
Air discharge
EN 61000-4-2 Test level 3
Electromagnetic fields
EN 61000-4-3 Test level 3
Fast transients
EN 61000-4-4 Test level 3
Surge voltage symmetrical
EN 61000-4-5 Test level 2
Surge voltage asymmetrical
EN 61000-4-5 Test level 3
Cable-based RF faults
EN 61000-4-6 Test level 3
Stability
Vibration
IEC 60068-2-6 Test FC, testing level in line with IEC 61131-2 E2 CDV
Germanischer Lloyd Guidelines for the Performance of Type Tests Part 1
Shock
IEC 60068-2-27 Test Ea, testing level in line with IEC 61131-2 E2 CDV
Network size
TP/TX port 10BASE-T/100BASE-TX
Length of a twisted pair segment
100 m (328 ft) maximum
Interfaces
8 TP/TX ports
RJ45 sockets, 10/100 MBit/s
Indicator contact
1 A maximum, 24 V
Displays
Equipment status
1 x green LED
P1
– power 1, supply voltage 1 present
1 x green LED
P2
– power 2, supply voltage 2 present
1 x red LED
FAULT
– indicator contact is open and indicates error
Port status
8 x green/yellow LED
DAT/STAT 1 to 8
– data, link status
Controls
8-pole DIP switch
LA1 to LA8
– suppress message about the link statuses
Scope of delivery
Rail Switch RS2-TX incl.
terminal block for supply voltage
description and operating instructions
Order number
Rail Switch RS2-TX 943 686-003
Accessories
ETHERNET manual
943 320-011
Manual
Basics
i
ETHERNET and TCP/IP
280 720-834
Rail Power Supply RPS 60
943 662-001
Rail Power Supply RPS 120
943 662-011
6
Summary of Contents for 943 686-003
Page 7: ...7 Notizen Notes...