Text
Text
Ready
Bit
Ok
Bit
Cancel
Bit
Time
Bit
Function:
With this function, if input
Show
has a rising edge the stored
text will be displayed at the terminal. Additionally you can set a
display time in seconds at input
Time
. If this time runs out,
output
Time
will be activated. If the input stays unconnected,
the time function will be ignored. Output
Ready
will be active
when the complete screen set-up is finished. If the user
presses the OK button, output
OK
will be activated. If the user
presses the Cancel button, output
Cance
l will be activated.
Input
Value
receives the character string which is displayed
instead of the # characters.
Objects: Terminal: Edit Text
Symbol:
Edit
Edit
EDIT TEXT
EDIT TEXT
Time
Time
EDIT TEXT
=========
Edit here:
#######
EDIT TEXT
=========
Edit here:
#######
Ready
Ready
Ok
Ok
Cancel
Cancel
Time
Time
Default
Default
Text
Text
Edit
Edit
EDIT TEXT
EDIT TEXT
Time
Time
EDIT TEXT
=========
Edit here:
#######
EDIT TEXT
=========
Edit here:
#######
Ready
Ready
Ok
Ok
Cancel
Cancel
Time
Time
Default
Default
Text
Text
Input:
Define the text, which should be delivered from the terminal.
4x20 characters are available. By entering # characters within
the text, you can mark the place for the text input.