www.HiotH.com
Specifications
1.
Radio protocol
:
Z-Wave
2.
Operating voltage
:
DC 3V (CR123A Lithium Battery)
3.
Static current
:≤
10
μ
A
4.
Alarm current
:≤
60mA
5.
Networking way
:
Z-Wave Ad-Hoc Network
6.
Sound level
:
85dB/3m
7.
RF range
:≤
70m (open area)
8.
Working Temperature
:
-10
℃
~+50
℃
9.
Working humidity
:≤
95%RH
10.
Dimension
:
60
60
49.2mm
Operation
As shown in figure 1, there is a Reset button (which is used to carry out inclusion, exclusion or
reset), a Test/Mute button and a network status indicator LED on the surface of the Smart
Photoelectric Smoke Sensor, and the functions are introduced as follows:
Networking Button (Reset Button)
(1) If the Smart Photoelectric Smoke Sensor has not been included into the network, short
press the Reset button to enter the network inclusion condition, at this time the network status
indicator LED flash (3 times/second). If the network inclusion success, the network status
indicator LED will long on for 2 seconds and then go out. If the network inclusion failure, the