Power Supply with Screw Counter 

 

VZOP-STC 

 

Instruction Manual 

(March    2009) 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

For VB-OPC screwdriver

   

                 

                       

For VZ-OPC screwdirver 

 
 

 

Hios Inc. 

111-6, Akiyama, Matsudo, Chiba Pref. Japan, 270-2223 

TEL: +86

Japan

47-392-2001

   

 

FAX: +86

Japan

47-392-7773 

 
 

09A 

                                                                               

     

 

Operation Manual No.ET-A009

Summary of Contents for VZOP-STC

Page 1: ...nter VZOP STC Instruction Manual March 2009 For VB OPC screwdriver For VZ OPC screwdirver Hios Inc 111 6 Akiyama Matsudo Chiba Pref Japan 270 2223 TEL 86 Japan 47 392 2001 FAX 86 Japan 47 392 7773 09A Operation Manual No ET A009 ...

Page 2: ...rator can also select a function that reverses increases the count if a reverse signal is input to the screwdriver to loosen the screws selected with mode SW3 Another option allows the reverse count up time to be set when screws are biting normally not counted This time can be set between 0 2 and 1 0 seconds A switch has been installed on the internal circuit board to allow the normal operator to ...

Page 3: ...ns 160 W x 175 D x 84 H Weight 1 5 Kg AC cord length 1 8 m with ground Supplied accessories 8 terminals 1 slotted screwdriver Compatible drivers VB OPC specification driver VB 1510 OPC VB 1820 OPC VB 3012 OPC including PS type VB 4504PS OPC VZ OPC specification driver VZ 1510 OPC VZ 1820 OPC VZ 3012 OPC Including PS type VZ 4506 OPC ...

Page 4: ...ent connected to the DC 24 V output terminal or input output terminals on the rear panel terminal block are affected by the electromagnetic induction of relays and solenoid valves coils noise prevention in the form of reverse voltage absorbing diodes should be used Equipment may operate incorrectly or malfunction if noise prevention is not used 4 Do not connect the 24 V DC terminals on the rear pa...

Page 5: ...n incorrect operation 12 Do not drop or subject the unit to strong shocks 13 Do not use drivers other than those manufactured by Hios Doing so may result in a malfunction 14 Turn the main power switch OFF if the unit is not used for a prolonged period of time and remove the power plug 15 Never dismantle or modify the unit by yourself Doing so may result in a malfunction and void the warranty or ma...

Page 6: ...e remaining Count Set SW This switch sets the number of screws to be tightened and can be set from 1 to 99 screws Set units of 10 and 1 individually Click the reset button once during or after setting the number of screws to confirm the screw count Rotate the supplied slotted screwdriver to change settings Count Timer This timer prevents incorrect screw counts when tightening a screw that has alre...

Page 7: ...peration of the solenoid valve 0 1 to 3 seconds Work Reset Timer Adjusts for the time between the completion of work and when the solenoid valve turns off A buzzer sounds at the same time 0 1 to 3 seconds Caution Do not apply excessive force when setting volume knobs or switches Doing so may result in a malfunction ...

Page 8: ...ue until work is complete or the unit is reset when the work piece is removed during operations before work is complete A warning can be generated by connecting an error buzzer BZ A signal generated in time with the buzzer when the final screw has been tightened open collector output DC 30 V 0 1A VALVE Used after the set input signal has been received and the solenoid valve DC 24 V has started ope...

Page 9: ...pacity is DC 24 V 0 3A Mode Switches 1 The work complete notification buzzer built in no longer sounds if switched OFF 2 The panel display turns off if switched OFF 3 The reverse rotation count up operation turns off if switched OFF 4 When switched OFF the unit will only work once the set input signal is received 5 Unused ...

Page 10: ...o DC 24 V and terminal to VALVE on the rear panel terminal block 3 Connect the switch contact point for releasing the work if operations are stopped to RESET and GND 4 Connect the driver and adjust CN T to a position that does not count down even if the driver is used to further tighten screws that have already been tightened 5 Adjust WS T to the time taken for the solenoid valve to operate after ...

Page 11: ...1 Connect the external switch to SET and GND on the rear panel terminal block no polarity if an external switch is used and common GND if an open collector is used before connecting the output signal to SET 2 Connect both A and B GND common GND 3 Connect A COMP and B SET 4 Set A mode SW1 to OFF so that the buzzer for A does not sound 5 Connect a total counter to B COMP and GND Work Rest Switch Wor...