  Safety Precautions

 Before using

  Before you begin using the instrument, read the 

operating instructions and also the precautions 

given on the seal af

fi

 xed to the instrument.

  HIOS cannot assume responsibility for ac-

cidents or dif

fi

 culties when the instrument has 

been remodeled or disassembled, or when it has 

been used in a way other than that explained in 

the operating instructions.  

 During operation

  Keep the working area orderly to ensure that 

extraneous objects do not become entangled 

when the screwdriver or other instrument being 

measured is operated.

  Never point the driver bit in any direction other 

than into the torque meter.

  If the torque meter shows any functioning ab-

normality, cease operation immediately and 

contact HIOS Corporation or your HIOS dealer.

  Operators of power tools should always button 

cuffs and shirt fronts and fasten zippers on ap-

parel when conducting operations.

  Operators of power tools should not wear gloves, 

as this interferes dangerously with having a 

proper grip on the tools.

  Precautions in operating a digital 

torque meter

  Never exceed the maximum torque levels indi-

cated in the speci

fi

 cations on page 14. Exceed-

ing capacity load levels by 120% will result in 

internal damage to the meter.

  The battery charger is for NiMH batteries only. Nev-

er use any other kind of battery, even from HIOS.

  Operating the Fidaptor

  See pages 10 and 11 concerning operation of 

the Fidaptor.

  Do not use this instrument for measurement of 

continuous impact tools like air drivers or im-

pact wrenches.*

  Do not disassemble the instrument or loosen the 

screws on its body, as this could cause inaccu-

racy in measurement.

  Use of the battery charger

  See page 12 for instructions on battery charging.

  Use only the products speci

fi

 ed in these operat-

ing instructions for connection to the data out-

put ports.

  When disconnecting cables, grasp the cable plug 

and take care not to damage connector pins.

  Always turn the power switch off after complet-

ing measurement operations.

  Do not strike the acrylic display panel or place 

heavy objects on it.

  Avoid excessive internal adjustments for cali-

brating or other purposes.

  Handle the instrument with care and take care 

not to drop it.

  This instrument is sensitive to ambient condi-

tions. Avoid using it in the following kinds of 

places:

 Places where water, oil or other liquids could 

fall onto or get inside the instrument.

  Places subject to vibration, dust or hot air.

 Outdoors, or places where electrical discharg-

es may occur.

 Places of high temperature or humidity. (Operat-

ing humidity and temperature ranges for digital 

torque meters are 25%

65% and 15

35

).

  Any other place where there is a danger of the 

instrument being damaged or its functioning 

impaired.

  Please do not store the instrument in places of 

high temperature or high humidity. This could 

result in condensation forming inside, which 

could endanger functioning.

*  HIOS offers other instruments for measurement 

of air drivers, impact wrenches, etc. Please con-

tact HIOS Corporation or your HIOS dealer for 

information.

Please read the following safety precautions 
to ensure safe and correct operation.

  Data can be output analogically, as waveforms 

or numerical printouts, for a wide range of uses. 

(Requires optional analog cord.)

  An input tool is available to make possible 

transfer of measurement data to a computer. (See 

page 13 for details.)

  Comes with an AC adapter that can be used 

with 100

 240 volt power sources. Runs on an 

environment-friendly nickel-hydrogen battery.

- 3 -

Summary of Contents for HP-1

Page 1: ...Digital Torque Meters HP 100 HP 10 HP 1 Option Operation Manual May 2019 ET C006 19A ...

Page 2: ...rs are used by manufacturers of electronic goods cameras watches and other kinds of precision instruments as well as by makers of automobiles and aircraft Applications Torque measurement of power screwdrivers torque drivers and torque wrenches Certification of performance of torque tools Torque measurement of other kinds of rotation tools may require adapter Examples of uses of torque measurement ...

Page 3: ...Use of the battery charger See page 12 for instructions on battery charging Use only the products specified in these operat ing instructions for connection to the data out put ports When disconnecting cables grasp the cable plug and take care not to damage connector pins Always turn the power switch off after complet ing measurement operations Do not strike the acrylic display panel or place heavy...

Page 4: ...a This functions makes it possible to use the DATA OUT instrument in statistical process control systems 2 DIP switch For setting auto reset timer and turning data output on P ON LED indicates on setting Torque set switch A SET Sets maximum torque load at which warning tone will sound Memory function toggle switch The LED lights when the memory function is on M_SET Torque set switch B Sets the tor...

Page 5: ...3N m Black spring Part No TF6XG Z 1 pc Hex shank Convertible shaft 5 mm sub tense Upper 6 35 mm subtense Lower Driver Shaft Part No TF6XG 0010 Part No TF5G 0010 4 Hex shank convertible shaft 5 mm subtense Upper 6 35 mm subtense Lower 1 pc 1 pc HIOS shank 4 Measuring range 0 15 0 6N m Yellow Spring Part No TF4G Z 1 pc Measuring range 0 15 0 6N m Yellow Spring Part No TF6SG Z 1 pc HIOS shank 4 Part ...

Page 6: ...of the Fidaptor in the operation manual and replace the Fidaptor driver shaft with a new one after 2 500 strokes at the point where the clutch disengages Features a safety cover and a mechanism that has almost the same effect as that obtained in actual tapping screw fastening work Limit Line on the Fidaptor TFG series How to Use The Fidaptor TFG series Threaded shaft comes with Model HP 100 Use as...

Page 7: ...spreadsheet application In order to output data please conduct measure ment within the instrument s peak measurement range as indicated in the specifications Minus signs denoting counterclockwise torque are transferred with the measurement data 8 Use the Fidaptor to measure torque of power screwdrivers as explained below 9 It is possible to fashion adapters for torque mea surement of other types o...

Page 8: ...ached This tone also sounds when the torque set ON ON Reset Setting Warning tone Track Peak Switch functions for setting torque Switches used SET switch 1 Press for 2 seconds to enter torque setting mode Press for 2 seconds once again to exit torque set ting mode 2 When the meter is in torque setting mode the 4 digit display can be adjusted one digit at a time Use the SET switch to select the digi...

Page 9: ...2 0003 0004 0001 0002 0003 0004 Fig 4 Full deletion of measurement data Partial deletion of measurement results Example of full deletion of measurement data Memory function on LED on measurement data in memory Ready for measurement M_CR switch M_CR switch Full data deletion mode display Press for 2 seconds Display flickers Exit full deletion mode RESET pressed or no action for 30 seconds Press onc...

Page 10: ...rage measurement mode and is deleted when the mode is terminated Each time the AVE switch is pressed minimum average and maxi mum values are displayed flickering Fig 1 Min Ave 1st measurement deleted 11th measurement recorded 0001 0002 0003 0010 0001 0002 0003 0009 0010 0001 0002 0003 0009 0010 Notes 1 Be sure to set MODE switch to PEAK or F PEAK before entering average measurement mode 2 The UNIT...

Page 11: ...t Guide to when it s time to replace Fidaptor parts Threaded shaft and bearing set After 2 500 strokes Threaded shaft only When it becomes bent or its threads are worn Spring Replace together with threaded shaft after 2 500 strokes Plate nut After 5 000 strokes Note 6 See that each measuring cycle lasts 5 seconds or more to minimize wearing of parts 7 Never attach the Fidaptor unless you intend to...

Page 12: ...e the battery Cautions in making a socket adapter Make sure that the adapter fits snugly into the socket Make sure the adapter is strong enough that it won t break during measurement Do not attempt to use an adapter that delivers more than 10 kg of vertical torque Do not use this torque meter to measure impact torque tools Take care to observe all other principles of torque measurement Do not use ...

Page 13: ...rformed This does not apply under circumstances 1 4 above Shipping and handling charges incurred for re pair service must be paid by the customer Please direct questions about customer services to HIOS Corporation or your HIOS dealer Attention The product that you have purchased contains a rechargeable battery The battery is recyclable At the end of it s useful life under various state and local l...

Page 14: ...ch on and see if there is a display If there is not contact HIOS or your HIOS dealer Conduct zero adjustment Set to PEAK Check that the plug is connected properly Connect to the battery charger socket If the above does not remedy the problem contact HIOS or your HIOS dealer Send to HIOS for repair Recharge the battery for no more than 6 hours Press RESET switch to clear the display Insufficient ba...

Page 15: ...ata output from the torque meter Sign Entry number Data type Decimal point position Measured value Unit mm As for the dimensions HP 1 10 and 100 are the same Note that specifications or the external ap pearance of HIOS torque meters are sub ject to change without notice External features diagram Max BZ Ave Min P ON SET Digital Torque Meter AVE M_CR M_SET PEAK TRAK POWER ON MODE UNIT RESET F PEAK 1...

Page 16: ...以下 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 In addition the China RoHS marks also is required at the product and product box At the product you can find it at the bottom and it is marked on the product box If you cannot find the mark please ask your distributor In case of emergency please cut the mark below and stick at the bottom of product and on the product box China RoHS mark Note minimum...

Page 17: ......

Page 18: ......

Page 19: ......

Page 20: ...HIOS Inc 1 35 1 Oshiage Sumida ku Tokyo Japan 131 0045 TEL 81 Japan 3 6661 8821 FAX 81 Japan 3 6661 8828 www hios com ...

Reviews: