Safety Precautions
■
Before using
Before you begin using the instrument, read the
operating instructions and also the precautions
given on the seal af
fi
xed to the instrument.
HIOS cannot assume responsibility for ac-
cidents or dif
fi
culties when the instrument has
been remodeled or disassembled, or when it has
been used in a way other than that explained in
the operating instructions.
■
During operation
Keep the working area orderly to ensure that
extraneous objects do not become entangled
when the screwdriver or other instrument being
measured is operated.
Never point the driver bit in any direction other
than into the torque meter.
If the torque meter shows any functioning ab-
normality, cease operation immediately and
contact HIOS Corporation or your HIOS dealer.
Operators of power tools should always button
cuffs and shirt fronts and fasten zippers on ap-
parel when conducting operations.
Operators of power tools should not wear gloves,
as this interferes dangerously with having a
proper grip on the tools.
■
Precautions in operating a digital
torque meter
Never exceed the maximum torque levels indi-
cated in the speci
fi
cations on page 14. Exceed-
ing capacity load levels by 120% will result in
internal damage to the meter.
The battery charger is for NiMH batteries only. Nev-
er use any other kind of battery, even from HIOS.
Operating the Fidaptor
See pages 10 and 11 concerning operation of
the Fidaptor.
Do not use this instrument for measurement of
continuous impact tools like air drivers or im-
pact wrenches.*
Do not disassemble the instrument or loosen the
screws on its body, as this could cause inaccu-
racy in measurement.
Use of the battery charger
See page 12 for instructions on battery charging.
Use only the products speci
fi
ed in these operat-
ing instructions for connection to the data out-
put ports.
When disconnecting cables, grasp the cable plug
and take care not to damage connector pins.
Always turn the power switch off after complet-
ing measurement operations.
Do not strike the acrylic display panel or place
heavy objects on it.
Avoid excessive internal adjustments for cali-
brating or other purposes.
Handle the instrument with care and take care
not to drop it.
This instrument is sensitive to ambient condi-
tions. Avoid using it in the following kinds of
places:
Places where water, oil or other liquids could
fall onto or get inside the instrument.
Places subject to vibration, dust or hot air.
Outdoors, or places where electrical discharg-
es may occur.
Places of high temperature or humidity. (Operat-
ing humidity and temperature ranges for digital
torque meters are 25%
−
65% and 15
℃
−
35
℃
).
Any other place where there is a danger of the
instrument being damaged or its functioning
impaired.
Please do not store the instrument in places of
high temperature or high humidity. This could
result in condensation forming inside, which
could endanger functioning.
* HIOS offers other instruments for measurement
of air drivers, impact wrenches, etc. Please con-
tact HIOS Corporation or your HIOS dealer for
information.
Please read the following safety precautions
to ensure safe and correct operation.
Data can be output analogically, as waveforms
or numerical printouts, for a wide range of uses.
(Requires optional analog cord.)
An input tool is available to make possible
transfer of measurement data to a computer. (See
page 13 for details.)
Comes with an AC adapter that can be used
with 100
−
240 volt power sources. Runs on an
environment-friendly nickel-hydrogen battery.
- 3 -
Summary of Contents for HP-1
Page 1: ...Digital Torque Meters HP 100 HP 10 HP 1 Option Operation Manual May 2019 ET C006 19A ...
Page 17: ......
Page 18: ......
Page 19: ......