The Torque Value Checking Meters

For Automatic Controlled System

HM-10

HM-100

Operation Manual

(As of December 2016)

1-16-5 Akiyama, Matsudo City, 
Chiba Pref., Japan
TEL:  81 (Japan) 47-392-2001
FAX:  81 (Japan) 47-392-7773

Summary of Contents for HM-10

Page 1: ...0 post consumer recycled paper pulp The Torque Value Checking Meters For Automatic Controlled System HM 10 HM 100 Operation Manual As of December 2016 1 16 5 Akiyama Matsudo City Chiba Pref Japan TEL 81 Japan 47 392 2001 FAX 81 Japan 47 392 7773 ...

Page 2: ...tion recording or judgment of measurement results an analog cord is optional Caution Read the notes below carefully for safe and proper use Before using this instrument Make sure to carefully read this operation manual and the notes attached to the instrument before use for safe and proper use The torque meter display unit and the detector are calibrated and controlled with the same serial number ...

Page 3: ...ly or drop it Do not use the detector in inappropriate places described below A place where water oil and other fluids may be scattered A place where vibrations dust or heat may exist Outdoors and a place where electric noises may exist A place with high temperatures and high humidity preferable temperature 15 C 35 C preferable humidity 25 65 Other places where malfunctions and functional damages ...

Page 4: ...ack Serial No sticker is attached Side of the detector Serial No sticker is attached DETECTOR Mode Switch TRACK The value on the display changes as the load to the detector changes The value will disappear when no load is applied PEAK The maximum value of load is captured The value will disappear when you press the reset button Buzzer Set The buzzer will start sounding when the torque reaches the ...

Page 5: ...ssory Optional accessory separately sold P N TFM 26 Z TFM 20 Z TFM 40 Z Measurement range N m 0 15 0 6 0 25 or smaller 0 5 3 Yellow spring Red spring Black spring Supporting bit No 1 0 2 Head screw diameter M2 6 P N SPP26 060SUS M2 6 P N SPC26 060 M4 0 P N SPP40 080SUS About Fidaptor accessories Use Fidaptor for torque measurement of the screwdriver for an automatically controlled system For 1 bit...

Page 6: ...the detector There are two connectors Use one of them considering the workability Make sure the connector has the correct shape If you ignore this it may cause pin bending Note There are two connectors Use one of them and cover the other one with a cap Points for fixing 4 Use the handy screwdriver to loosen the threaded shaft ring of Fidaptor a little A spring loosens Loosen the shaft so that you ...

Page 7: ...trolled system it should be aligned with the center of the Z axis 6 Set the switch for measurement unit change to your desired unit MODE TRAK PEAK RESET OFF O N POWER MADE IN JAPAN N m lbf in kgf cm HM Unit converter Switch 7 Set the mode switch to TRACK and turn the zero adjustment knob for zero adjustment MODE TRAK PEAK RESET OFF O N POWER MADE IN JAPAN N m lbf in kgf cm HM Turn the knob for zer...

Page 8: ...onstant height 11 Cancel the value in the window by pushing the Reset button MODE TRAK PEAK RESET OFF O N POWER MADE IN JAPAN RESET button for cancelling the value Note for resetting 1 Let Fidaptor return to the constant height before pushing the RESET button for cancelling the value 2 Let the socket section have no load Note It cannot be reset if there is a load N m lbf in kgf cm HM 12 Repeat the...

Page 9: ... is required If you press the Reset button the data will be output and the value in the display window will be cancelled For the data output tool refer to the description on page 16 About digit digit means the unit of a value to be displayed regardless of the decimal point Examples 0 01 1 digit 025 25 digits 10 10 digits 1 25 125 digits ...

Page 10: ...ting the buzzer 1 Apply load to the detector 2 When the load reaches the preset value the buzzer starts and In the case of the TRACK mode The buzzer stops when you release the load zero is displayed In the case of the PEAK mode The buzzer and the display continue even when you release the load You can stop the buzzer and the display by pressing the Reset button When you don t use the buzzer settin...

Page 11: ...en the spring 8 Correctly engage the object for measurement and Fidaptor 9 Don t use a deformed or modified Fidaptor Maintenance and inspection of Fidaptor 1 Apply grease to the components 1 2 and 5 see the figure below of Fidaptor regularly 2 Check the components below before you use Fidaptor 1 The components 1 2 and 5 have been greased 2 The threaded shaft is not bent and the threads have not wo...

Page 12: ...lease read the following carefully Do not charge the battery longer than eight hours Use only NiMH batteries never any other kind even if obtained from HIOS Corporation Do not use the instrument while charging the battery When LOBAT is displayed in the window stop measurement and charge the battery Do not use the dedicated charger for other purposes Do not place anything heavy on the cord of the c...

Page 13: ...idaptor etc 2 No charge will be made for service in the case of inspection and or calibration of the same part that becomes necessary within three months after inspection or calibration has been performed This does not apply under circumstances 1 4 above Shipping and handling charges incurred for repair service must be paid by the customer Please direct questions about customer services to HIOS Co...

Page 14: ...s zero adjustment in the TRACK mode occasionally while in operation The value cannot be held The Mode switch is set to TRACK Set it to PEAK Zero adjustment has not been done The connection cable is wrongly connected or it is broken Use the zero adjustment knob for adjustment Replace the cable The instrument cannot be charged The plug of the charger is not inserted correctly Check if the plug is co...

Page 15: ...us operating time on a full charge 30 hours Battery life 300 cycles of charging Detector cord 1 7m 6P cord P N DPC 0506 Exclusive battery charger Input AC100V 120V 220 240V Output DC7 2V 120mA P N TCH 100N Never apply the load more than the maximum allowable load We cannot guarantee the life of the battery in the specification table because it varies depending on the usage pattern Instruments for ...

Page 16: ... 15 Outline dimensional drawing and detailed socket dimensions 2 3 26 35 30 Note The dimensions of the detector in this drawing are not full scale unit mm Detector Main unit ...

Page 17: ... the devices properly after reading the operation manuals attached to the devices Data output If you want to transfer the data to your PC please use the input tool of Mitutoyo A connection cable separately sold is also required to connect the input tool and the torque meter Types of input tools USB keyboard conversion type P N IT 012U 264 012 Keyboard signal conversion type P N IT 005D 264 005 for...

Page 18: ...en drain 0 3 to 7V 400μA max it is pulled up to VDD 1 55V 2 Data output format 13 digits are output in the sequence below d1 d2 d3 d4 d5 d6 d7 d8 d9 d10 d11 d12 d13 Sign Entry number Data type Decimal point position Measured value Each digit is expressed with a 4 bit binary and output from LSB in the sequence 20 2 1 2 2 2 3 3 Timing chart MIN MAX UNIT T0 2 sec T1 0 2 0 4 sec T2 0 2 0 4 mS T3 0 5 1...

Page 19: ...表示该有害物质在该部件所有均质材料中的含量均在 GB T 26572 规定的限量要求以下 表示该有害物质至少在该部件的某一均质材料中的含量超出 GB T 26572 规定的限量要求 In addition the China RoHS marks also is required at the product and product box At the product you can find it at the bottom and it is marked on the product box If you cannot find the mark please ask your distributor In case of emergency please cut the mark below and stick at the bottom of product and on th...