47
6
Initialization
6.1 Initialization Settings
The device is in the initial state at the time of shipment and at the time of initialization using
commands. However, communications settings will not be initialized if the initialization is triggered
by command.
Settings that are backed up can be stored so that they persist even when the power is turned off by
executing the
:SYSTem:BACKup
command.
See: “Backing up settings” (p. 105)
Communications settings are backed up even if the
:SYSTem:BACKup
command is not executed.
: Yes, –: No
Item
Initialization description
Backup
Channel relay
All relays open
–
Bus relay
All relays open
–
EXT. I/O CLOSE output signal
OFF
–
Connection method
SW9001: 2-wire
SW9002: 4-terminal pair
Shield switching
SW9001:
TERMINAL 1
, LOW terminal
SW9002:
TERMINAL 3
, sense shield terminal
Channel delay settings
0.0 s
Scan list
None
Scan operation trigger source
STEP
Query forwarding timeout
10 s
EXT. I/O filter function
OFF, 0.05 s
Pulse width of CLOSE output
signal
0.005 s
Communication settings (USB)
(No setting item)
–
Communication settings
(RS-232C)
9600 bps
Communication settings (LAN)
User setting mode (setting switch:
USER
)
IP address:
192.168.0.254
Subnet mask:
255.255.255.0
Default gateway:
0.0.0.0 (None)
Communication command port number:
23
Fixed setting mode (setting switch:
DFLT
)
–
IP address:
192.168.0.254
Subnet mask:
255.255.255.0
Default gateway:
0.0.0.0 (None)
Communication command port number:
23
6 Initialization
6
Initialization
HIOKI SW1001A961-04
Summary of Contents for SW9001
Page 2: ...HIOKI SW1001A961 04...
Page 42: ...38 Channel Delay Function HIOKI SW1001A961 04...
Page 48: ...44 Scan Measurement Example HIOKI SW1001A961 04...
Page 50: ...46 Checking the Device Status HIOKI SW1001A961 04...
Page 52: ...48 Initialization Settings HIOKI SW1001A961 04...
Page 118: ...114 Sample Programs 3 Select FILE Save All HIOKI SW1001A961 04...
Page 160: ...156 Outline Drawings 12 4 Outline Drawings SW1001 Unit mm Tolerance 0 2 HIOKI SW1001A961 04...
Page 161: ...157 Outline Drawings SW1002 Unit mm Tolerance 0 2 12 Appendix HIOKI SW1001A961 04...
Page 162: ...158 Outline Drawings HIOKI SW1001A961 04...
Page 164: ...160 HIOKI SW1001A961 04...
Page 167: ...HIOKI SW1001A961 04...
Page 168: ...HIOKI SW1001A961 04...
Page 169: ...HIOKI SW1001A961 04...