background image

RESISTANCE METER  

RM3545, RM3544

 

Basic accuracy :  0.006%

  

 

No. of display digits: 

Max. 6.5

 

Max.resolution : 0.01μΩ   (

LP) 

0.01mΩ

 

Basic accuracy :  0.02

%    

 

No. of display digits: 

Max. 4.5

 

Max.resolution : 

1μΩ

Featuring super-high accuracy and multi-channel capabilities  

(20 channels with 4-terminal measurement)

RESISTANCE METER RM3545

RESISTANCE METER RM3544

High-accuracy bench-top meter ideal for production lines

Summary of Contents for RM3544

Page 1: ...tion 0 01 LP 0 01m Basic accuracy 0 02 No of display digits Max 4 5 Max resolution 1 Featuring super high accuracy and multi channel capabilities 20 channels with 4 terminal measurement RESISTANCE MET...

Page 2: ...or both manual operation and integration with automatic lines Max measurable current 1A Max resolution 0 01 Basic accuracy 0 006 Resistance measurement Max measurable current 1mA Max Open circuit volt...

Page 3: ...on Pictured Back of the RM3545 02 with two Z3003 units optional feature installed Insert up to two Z3003 units into the slots on the back of the instrument Multi point measurement with the Multiplexer...

Page 4: ...immediately after startup without any warm up or zero adjustment When performing measurement with the RM3545 in a temperature and humidity environ ment that satisfies the guaranteed accuracy condition...

Page 5: ...act resistance indi cates an error Time R RM3545 Logger Auto scanning and step scanning When using the Multiplexer Unit Z3003 to perform scanning measure ment you can select either step scanning or au...

Page 6: ...or saving and loading panels The RM3545 RM3544 can save and load up to 30 10 sets of range comparator and other settings Naming each set of panel data lets you make setup changes among production lots...

Page 7: ...d to toggle the input signal polar ity between NPN sink output support and PNP source output support settings depending on the PLC common polarity EXT I O Input and Output Circuits EXT I O polarity Se...

Page 8: ...ternal I O comparator BCD BIN function 3 3 3 Communication interfaces RS 232C Printer USB 3 3 3 GP IB N A 3 N A Multiplexer scanner function N A N A 3 Max 20 channels When using 4 terminal measurement...

Page 9: ...rminal settings Front terminals MUX multiplexer When using the MUX setting the measurement leads cannot be connected to the front measurement terminals Support unit Z3003 Number of channels that can b...

Page 10: ...0 m 0 008 0 005 0 007 0 002 0 007 0 001 1mA 20V 100k 120 000 0 k 100 m 0 008 0 005 0 007 0 002 0 007 0 001 100 A 1000k 1200 000 k 1 0 015 0 005 0 008 0 002 0 008 0 001 10 A 10M 12 000 00 M 10 0 030 0...

Page 11: ...k 0 020 0 010 0 020 0 007 1mA 30k 35 000 k 0 020 0 010 0 020 0 007 100 A 300k 350 00 k 0 040 0 010 0 040 0 007 5 A 3M 3 500 0 M 0 200 0 010 0 200 0 007 500nA 6 For negative values to 10 f s 7 The maxi...

Page 12: ...TTACHMENT L2105 2 m 6 56 ft RS 232C CABLE 9637 for PC connection 9pin 9pin cross 1 8 m 5 91 ft RS 232C CABLE 9638 for PC connection 9pin 25pin cross 1 8 m 5 91 ft GP IB CONNECTOR CABLE 9151 02 2 m 6 5...