101
Changing the Waveform Display and Configuring Recording
Description of parameter settings and selectable ranges
Parameter
Settings
Description
Auto trigger
ON
Waveform recording will be forcibly started if the next trigger is
not activated within 100 ms after the activation of the previous
trigger. This setting is useful to observe DC input waveforms.
OFF
Waveform recording starts only when the set condition is met.
Pre trigger[%]
0%
to
100%
(Can be set in 10 percent
points increments.)
Sets how much of the waveform to allocate before the trigger
is activated, relative to the recording length.
T
Start trigger
Pre-trigger
Pre-trigger setting
Recording length
Configure the settings by rotating the X rotary knob.
See “Changing values with rotary knobs” (p. 21).
Source
Sets the waveform to use as the trigger source.
U1
to
U8
Voltage waveforms
I1
to
I8
Current waveforms
CH A
to
CH H
,
Ext1
to
Ext4
Motor waveforms (available only for motor analysis-equipped
model)
Available settings vary with the motor input operating mode.
ZCF
(
Zero-cross filter)
ON
,
OFF
This function can eliminate noises of a waveform used as the
trigger source by a noise filter when the trigger source setting
is set to voltage waveform or current waveform.
Set
[ZCF]
to
[ON]
to obtain stable trigger timing when using a
waveform containing noise.
This setting is particularly effective to observe PWM
waveforms.
This does not affect the display waveform.
If
[Source]
is set to Ch. A to Ch. H or Ext1 to Ext4, the ZCF is
forcibly disabled.
Slope
Rising
The trigger will be activated at a rising edge of the waveform.
Falling
The trigger will be activated at a falling edge of the waveform.
Level[%]
−300%
to
+300%
Sets the level at which the trigger is activated using a
percentage of the source range. A level monitor appears on
the right side of the window.
This setting cannot be used when the trigger source is set to
[Pulse]
of a motor waveform.
Configure the settings by rotating the Y rotary knob.
Lit up in green: in 0.1 increments
Lit up in red: in 1 increments
See “Changing values with rotary knobs” (p. 21).
You can move the trigger level line after tapping it.
Displaying W
aveforms
HIOKI PW8001A961-00
Summary of Contents for PW8001-01
Page 2: ...HIOKI PW8001A961 00...
Page 6: ...Contents iv HIOKI PW8001A961 00...
Page 56: ...50 Checking Connections HIOKI PW8001A961 00...
Page 120: ...114 Power Calculation Method HIOKI PW8001A961 00...
Page 162: ...156 Controlling Integration with External Signals HIOKI PW8001A961 00...
Page 236: ...230 U7005 15MS s Input Unit HIOKI PW8001A961 00...
Page 258: ...252 Index HIOKI PW8001A961 00...
Page 259: ...HIOKI PW8001A961 00...
Page 260: ...HIOKI PW8001A961 00...
Page 261: ...HIOKI PW8001A961 00...
Page 262: ...www hioki com HIOKI PW8001A961 00...