![Hioki MR8904 Instruction Manual Download Page 58](http://html1.mh-extra.com/html/hioki/mr8904/mr8904_instruction-manual_2137100058.webp)
6.3 Checking Logic Channel Allocation
54
You can check logic channel allocation as configured with the MR8904 CAN Editor.
1
Display
[Setting Display]
[Channel]
[Logic]
on the MR8875.
2
Select the channel to which CAN definitions were allocated.
The following information will be displayed:
6.3
Checking Logic Channel Allocation
1
2
Port
Number of the port with which data will be received
ID
Message ID to receive
Signal
Name associated with received messages
Label
Identifying label associated with received messages
Bit Assign
Indicates how many bits from the LSB* of the received message to
measure. When an ID trigger has been allocated, displays “ID trigger.”
*: See "How to count the bit position" (p.28).
Start Send Frame
Selects the timing at which to send messages.
See:
"6.4 Setting the Transmission Timing" (p.55)
The display position can be selected as follows:
• When the logic recording width is
[Normal]
, Pos1 / Pos2.
• When the logic recording width is
[Wide]
, Pos1.
Summary of Contents for MR8904
Page 1: ...MR8904 Instruction Manual CAN UNIT EN Sept 2018 Revised edition 3 MR8904A981 03 18 09H...
Page 2: ......
Page 10: ...Usage Notes 6...
Page 14: ...10...
Page 24: ...3 3 Connecting the Unit to a PC 20...
Page 66: ...7 4 MR8904 CAN Editor General Specifications 62...
Page 69: ......
Page 70: ......
Page 71: ......
Page 72: ......